- PST300-600-70T
ABB PST300-600-70T softstarter, manufacturer ID 1SFA894014R7020, product main type PST300. Main circuit rated operational voltage is 208 to 600 V AC at 50/60 Hz. Rated control supply voltage is 100 to 250 V AC; rated control circuit voltage for DC operation is 24 V. In-line connection ratings are 300 A and 160 kW at 400 V, 200 kW at 500 V. Inside delta connection ratings are 515 A, 257 kW at 400 V and 355 kW at 500 V. Built-in electronic overload protection is included, with adjustable rated motor current 30 to 115 percent and service factor 115 percent. Starting capacity is 3xIe for 15 s. Ramp time is 0 to 120 s or 1 to 120 s; initial voltage during start is 30 to 70 percent. Dimensions are 360 mm width, 420 mm height, 270 mm depth; net weight 23 kg.
- PST300-690-70
The ABB PST300-690-70 is a softstarter for in-line or inside-delta connection. In-line ratings are 300 A and 160 kW at 400 V, 200 kW at 500 V, and 257 kW at 690 V. Inside-delta ratings are 515 A and 257 kW at 400 V, 355 kW at 500 V, and 500 kW at 690 V. The main circuit accepts 400 to 690 V AC at 50/60 Hz. Control supply is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a 115 percent service factor. Starting capacity is 3xIe for 15 s. Ramp time is 1 to 120 s, initial voltage 30 to 70 percent. Dimensions are 360 x 420 x 270 mm; net weight 23 kg.
- PST37-600-70
ABB PST37-600-70 soft starter, manufacturer ID 1SFA894003R7000. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz. Rated operational current in-line connection 37 A; inside delta connection 64 A. Rated operational power in-line connection 18.5 kW at 400 V and 22 kW at 500 V; inside delta connection 30 kW at 400 V and 37 kW at 500 V. Rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent. Starting capacity 3xIe for 15 s. Ramp time 1 to 120 s. Initial voltage during start 30 to 70 percent. Dimensions 160 mm wide, 260 mm high, 196 mm deep; net weight 4.8 kg.
- PST37-600-70T
ABB PST37-600-70T softstarter, manufacturer ID 1SFA894003R7020, is a spare part in the PST37 product main type. It measures 160 mm wide, 260 mm high, and 196 mm deep, weighing 4.8 kg. The main circuit is rated 208 to 600 V AC at 50/60 Hz, with control supply voltage 100 to 250 V AC and control circuit voltage 24 V DC. In-line connection ratings are 37 A and 18.5 kW at 400 V, 22 kW at 500 V. Inside delta connection ratings are 64 A, 30 kW at 400 V, and 37 kW at 500 V. Built-in electronic overload protection is included, with adjustable rated motor current 30 to 115 percent and service factor 115 percent. Starting capacity is 3xIe for 15 s; ramp time 0 to 120 s.
- PST37-690-70
The ABB PST37-690-70 soft starter is a spare part for soft starter assemblies, identified by manufacturer ID 1SFA895003R7000. Its main circuit is rated 400 to 690 V AC at 50/60 Hz, with control supply voltage 100 to 250 V AC and control circuit voltage 24 V DC. In-line connection ratings are 37 A and 18.5 kW at 400 V, 22 kW at 500 V, and 30 kW at 690 V. Inside-delta connection ratings are 64 A and 30 kW at 400 V, 37 kW at 500 V, and 55 kW at 690 V. It includes built-in electronic overload protection, adjustable rated motor current from 30 to 115 percent, and a service factor of 115 percent. Dimensions are 160 mm width, 260 mm height, and 196 mm depth, weighing 4.8 kg.
- PST37-690-70T
ABB PST37-690-70T softstarter, manufacturer ID 1SFA895003R7020, product main type PST37. Main circuit rated operational voltage is 400 to 690 V AC at 50/60 Hz. In-line connection ratings are 37 A and 18.5 kW at 400 V, 22 kW at 500 V, and 30 kW at 690 V. Inside-delta connection ratings are 64 A and 30 kW at 400 V, 37 kW at 500 V, and 55 kW at 690 V. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a 115 percent service factor. Starting capacity is 3xIe for 15 s. Dimensions are 160 mm wide, 260 mm high, and 196 mm deep; net weight is 4.8 kg.
- PST44-600-70
ABB PST44-600-70 soft starter, manufacturer ID 1SFA894004R7000. Main circuit rated operational voltage is 208 to 600 V AC at 50/60 Hz; rated control supply voltage is 100 to 250 V AC, with a 24 V DC control circuit. In-line connection ratings are 44 A and 22 kW at 400 V, 25 kW at 500 V. Inside-delta connection ratings are 76 A and 37 kW at 400 V, 45 kW at 500 V. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a 115 percent service factor. Starting capacity is 3xIe for 15 s. Ramp time is 0 to 120 s, initial voltage 30 to 70 percent, step-down voltage 100 to 30 percent. Dimensions are 160 mm wide, 260 mm high, 196 mm deep; net weight 4.8 kg.
- PST44-600-70T
ABB PST44-600-70T softstarter, manufacturer ID 1SFA894004R7020, is a spare part in the PST44 product main type. It measures 160 mm wide, 260 mm high, and 196 mm deep, weighing 4.8 kg. The main circuit is rated 208 to 600 V AC at 50/60 Hz, with a control supply voltage of 100 to 250 V AC and a control circuit voltage of 24 V DC. In-line connection ratings are 44 A and 22 kW at 400 V or 25 kW at 500 V; inside delta connection ratings are 76 A and 37 kW at 400 V or 45 kW at 500 V. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a service factor of 115 percent. Starting capacity is 3xIe for 15 s.