- PST44-600-70
ABB PST44-600-70 soft starter, manufacturer ID 1SFA894004R7000. Main circuit rated operational voltage is 208 to 600 V AC at 50/60 Hz; rated control supply voltage is 100 to 250 V AC, with a 24 V DC control circuit. In-line connection ratings are 44 A and 22 kW at 400 V, 25 kW at 500 V. Inside-delta connection ratings are 76 A and 37 kW at 400 V, 45 kW at 500 V. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a 115 percent service factor. Starting capacity is 3xIe for 15 s. Ramp time is 0 to 120 s, initial voltage 30 to 70 percent, step-down voltage 100 to 30 percent. Dimensions are 160 mm wide, 260 mm high, 196 mm deep; net weight 4.8 kg.
- PST44-600-70T
ABB PST44-600-70T softstarter, manufacturer ID 1SFA894004R7020, is a spare part in the PST44 product main type. It measures 160 mm wide, 260 mm high, and 196 mm deep, weighing 4.8 kg. The main circuit is rated 208 to 600 V AC at 50/60 Hz, with a control supply voltage of 100 to 250 V AC and a control circuit voltage of 24 V DC. In-line connection ratings are 44 A and 22 kW at 400 V or 25 kW at 500 V; inside delta connection ratings are 76 A and 37 kW at 400 V or 45 kW at 500 V. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a service factor of 115 percent. Starting capacity is 3xIe for 15 s.
- PST44-690-70
ABB PST44-690-70 softstarter, manufacturer ID 1SFA895004R7000, is a spare part in the PST44 product main type. It measures 160 mm wide, 260 mm high, and 196 mm deep, weighing 4.8 kg. The main circuit is rated 400 to 690 V AC at 50/60 Hz, with a rated control circuit voltage of 24 V DC. In-line connection ratings are 44 A and 22 kW at 400 V, 25 kW at 500 V, and 37 kW at 690 V. Inside delta connection ratings are 76 A and 37 kW at 400 V, 45 kW at 500 V, and 59 kW at 690 V. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a service factor of 115 percent.
- PST44-690-70T
ABB PST44-690-70T softstarter, manufacturer ID 1SFA895004R7020, product main type PST44. Main circuit rated operational voltage 400 to 690 V AC at 50/60 Hz; rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. In-line connection: 44 A rated operational current, with rated operational power 22 kW at 400 V, 25 kW at 500 V, and 37 kW at 690 V. Inside delta connection: 76 A, with 37 kW at 400 V, 45 kW at 500 V, and 59 kW at 690 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 0 to 120 s, initial voltage 30 to 70 percent. Dimensions 160 x 260 x 196 mm; net weight 4.8 kg.
- PST50-600-70
ABB PST50-600-70 soft starter, manufacturer ID 1SFA894005R7000, product main type PST50. Main circuit rated operational voltage is 208 to 600 V AC at 50/60 Hz. Rated control supply voltage is 100 to 250 V AC; rated control circuit voltage is 24 V DC. In-line connection ratings are 50 A and 25 kW at 400 V, 30 kW at 500 V. Inside delta connection ratings are 85 A and 45 kW at 400 V, 55 kW at 500 V. Adjustable rated motor current is 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s. Ramp time 0 to 120 s, initial voltage 30 to 70 percent. Built-in electronic overload protection. Dimensions 160 x 260 x 196 mm, weight 4.8 kg.
- PST50-600-70T
The ABB PST50-600-70T softstarter (manufacturer ID 1SFA894005R7020) is a spare part for motor control. The main circuit is rated 208 to 600 V AC at 50/60 Hz, with a control supply voltage of 100 to 250 V AC and a control circuit voltage of 24 V DC. In-line connection ratings are 50 A and 25 kW at 400 V or 30 kW at 500 V. Inside-delta connection ratings are 85 A and 45 kW at 400 V or 55 kW at 500 V. It includes built-in electronic overload protection, an adjustable rated motor current of 30 to 115 percent, a service factor of 115 percent, and a starting capacity of 3xIe for 15 s. Dimensions are 160 mm wide, 260 mm high, and 196 mm deep, weighing 4.8 kg.
- PST50-690-70
ABB PST50-690-70 soft starter, manufacturer ID 1SFA895005R7000. Rated operational voltage is 400 to 690 V AC in the main circuit at 50/60 Hz, with control supply voltage 100 to 250 V AC and control circuit voltage 24 V DC. In-line connection ratings are 50 A and 25 kW at 400 V, 30 kW at 500 V, and 45 kW at 690 V. Inside delta connection ratings are 85 A and 45 kW at 400 V, 55 kW at 500 V, and 75 kW at 690 V. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a 115 percent service factor. Starting capacity is 3xIe for 15 s. Dimensions are 160 mm wide, 260 mm high, and 196 mm deep, weighing 4.8 kg.
- PST50-690-70T
ABB PST50-690-70T softstarter, manufacturer ID 1SFA895005R7020, product main type PST50. Main circuit rated operational voltage is 400 to 690 V AC at 50/60 Hz. In-line connection: rated operational current 50 A, rated operational power 25 kW at 400 V, 30 kW at 500 V, and 45 kW at 690 V. Inside delta connection: 85 A, 45 kW at 400 V, 55 kW at 500 V, and 75 kW at 690 V. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70 percent. Dimensions 160 x 260 x 196 mm; weight 4.8 kg.