- PST50-690-70
ABB PST50-690-70 soft starter, manufacturer ID 1SFA895005R7000. Rated operational voltage is 400 to 690 V AC in the main circuit at 50/60 Hz, with control supply voltage 100 to 250 V AC and control circuit voltage 24 V DC. In-line connection ratings are 50 A and 25 kW at 400 V, 30 kW at 500 V, and 45 kW at 690 V. Inside delta connection ratings are 85 A and 45 kW at 400 V, 55 kW at 500 V, and 75 kW at 690 V. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a 115 percent service factor. Starting capacity is 3xIe for 15 s. Dimensions are 160 mm wide, 260 mm high, and 196 mm deep, weighing 4.8 kg.
- PST50-690-70T
ABB PST50-690-70T softstarter, manufacturer ID 1SFA895005R7020, product main type PST50. Main circuit rated operational voltage is 400 to 690 V AC at 50/60 Hz. In-line connection: rated operational current 50 A, rated operational power 25 kW at 400 V, 30 kW at 500 V, and 45 kW at 690 V. Inside delta connection: 85 A, 45 kW at 400 V, 55 kW at 500 V, and 75 kW at 690 V. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70 percent. Dimensions 160 x 260 x 196 mm; weight 4.8 kg.
- PST60-600-70
ABB PST60-600-70 softstarter spare part, manufacturer ID 1SFA894006R7000. Main circuit rated 208 to 600 V AC at 50/60 Hz. In-line connection: 60 A, 30 kW at 400 V and 37 kW at 500 V. Inside delta connection: 105 A, 55 kW at 400 V and 75 kW at 500 V. Control supply 100 to 250 V AC; control circuit 24 V DC. Built-in electronic overload protection, adjustable motor current 30 to 115 percent, service factor 115 percent. Starting capacity 3xIe for 15 s; current limit 1.5 to 7xIe; ramp time 1 to 120 s; initial voltage 30 to 70 percent. Screw terminals, main circuit 1 x 10 to 95 mm². Dimensions 160 x 260 x 196 mm, 5 kg. Operating ambient 0 to +50 °C.
- PST60-600-70T
ABB PST60-600-70T softstarter, manufacturer ID 1SFA894006R7020. Main circuit rated operational voltage 208 to 600 V AC; rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC; rated frequency 50/60 Hz. In-line connection: rated operational current 60 A, rated operational power 30 kW at 400 V and 37 kW at 500 V. Inside-delta connection: rated operational current 105 A, rated operational power 55 kW at 400 V and 75 kW at 500 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 0 to 120 s, initial voltage 30 to 70 percent. Dimensions 160 x 260 x 196 mm; weight 5 kg.
- PST60-690-70
ABB PST60-690-70 softstarter, manufacturer ID 1SFA895006R7000. Main circuit rated operational voltage 400 to 690 V AC at 50/60 Hz. In-line connection: rated operational current 60 A, rated operational power 30 kW at 400 V, 37 kW at 500 V, and 55 kW at 690 V. Inside delta connection: 105 A, 55 kW at 400 V, 75 kW at 500 V, and 90 kW at 690 V. Rated control circuit voltage is 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent. Starting capacity 3xIe for 15 s, current limit 1.5 to 7xIe, ramp time 1 to 120 s, initial voltage 30 to 70 percent. Dimensions 160 x 260 x 196 mm, weight 5 kg.
- PST60-690-70T
ABB softstarter spare part, display model PST60-690-70T, product main type PST60, manufacturer ID 1SFA895006R7020. Main circuit rated operational voltage is 400 to 690 V AC at 50/60 Hz, with rated operational current 60 A for in-line connection and 105 A for inside delta connection. Rated operational power is 30 kW at 400 V, 37 kW at 500 V and 55 kW at 690 V in-line, and 55 kW at 400 V, 75 kW at 500 V and 90 kW at 690 V inside delta. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection is included, with adjustable rated motor current 30 to 115 percent. Dimensions are 160 mm width, 260 mm height and 196 mm depth; net weight 5 kg.
- PST72-600-70
The ABB PST72-600-70 softstarter (manufacturer ID 1SFA894007R7000) is a spare part for softstarter applications. It measures 160 mm wide, 260 mm high, and 196 mm deep, weighing 5 kg. The main circuit is rated 208 to 600 V AC at 50/60 Hz, with a control supply voltage of 100 to 250 V AC and a control circuit voltage of 24 V DC. In-line connection ratings are 72 A and 37 kW at 400 V, 45 kW at 500 V. Inside delta connection ratings are 124 A, 59 kW at 400 V, and 80 kW at 500 V. It includes built-in electronic overload protection, adjustable rated motor current from 30 to 115 percent, a service factor of 115 percent, and starting capacity of 3xIe for 15 seconds.
- PST72-600-70T
ABB PST72-600-70T softstarter, manufacturer ID 1SFA894007R7020, product main type PST72. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz; rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. In-line connection: rated operational current 72 A, rated operational power 37 kW at 400 V and 45 kW at 500 V. Inside delta connection: 124 A, 59 kW at 400 V and 80 kW at 500 V. Built-in electronic overload protection with adjustable rated motor current 30 to 115 percent and service factor 115 percent. Starting capacity 3xIe for 15 s. Ramp time 1 to 120 s, initial voltage 30 to 70 percent, step-down voltage 100 to 30 percent. Dimensions 160 x 260 x 196 mm; weight 5 kg.