- PST72-600-70T
ABB PST72-600-70T softstarter, manufacturer ID 1SFA894007R7020, product main type PST72. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz; rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. In-line connection: rated operational current 72 A, rated operational power 37 kW at 400 V and 45 kW at 500 V. Inside delta connection: 124 A, 59 kW at 400 V and 80 kW at 500 V. Built-in electronic overload protection with adjustable rated motor current 30 to 115 percent and service factor 115 percent. Starting capacity 3xIe for 15 s. Ramp time 1 to 120 s, initial voltage 30 to 70 percent, step-down voltage 100 to 30 percent. Dimensions 160 x 260 x 196 mm; weight 5 kg.
- PST72-690-70
ABB softstarter spare part, display model PST72-690-70, product main type PST72, manufacturer ID 1SFA895007R7000. Main circuit rated operational voltage 400 to 690 V AC at 50/60 Hz; rated control circuit voltage 24 V DC. In-line connection: rated operational current 72 A, rated operational power 37 kW at 400 V, 45 kW at 500 V, 59 kW at 690 V. Inside delta connection: 124 A, 59 kW at 400 V, 80 kW at 500 V, 110 kW at 690 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s. Dimensions 160 x 260 x 196 mm, net weight 5 kg. Main terminals IP10 per IEC 60529, IEC 60947-1, EN 60529.
- PST72-690-70T
ABB PST72-690-70T soft starter, manufacturer ID 1SFA895007R7020, main type PST72. Main circuit rated 400 to 690 V AC at 50/60 Hz; control supply 100 to 250 V AC, control circuit 24 V DC. In-line connection: 72 A, 37 kW at 400 V, 45 kW at 500 V, 59 kW at 690 V. Inside delta connection: 124 A, 59 kW at 400 V, 80 kW at 500 V, 110 kW at 690 V. Built-in electronic overload protection, adjustable motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 0 to 120 s, current limit 1.5 to 7xIe. Dimensions 160 x 260 x 196 mm, 5 kg. Main terminals IP10 per IEC 60529, IEC 60947-1, EN 60529. Screw terminals, ambient operation 0 to +50 degrees C.
- PST72-70D
The ABB PST72-70D is a soft starter spare part in the PST72 series, manufacturer ID 1SFA894007R7009. It supports control via hardware inputs and keypad. Net weight is 0.01 kg, with net width, height, and depth each stated as 0 mm.
- PST85-600-70
ABB PST85-600-70 softstarter, manufacturer ID 1SFA894008R7000. Main circuit rated operational voltage is 208 to 600 V AC at 50/60 Hz. Rated control supply voltage is 100 to 250 V AC; rated control circuit voltage is 24 V DC. In-line connection ratings are 85 A and 45 kW at 400 V, 55 kW at 500 V. Inside delta connection ratings are 147 A and 75 kW at 400 V, 90 kW at 500 V. Adjustable rated motor current is 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 0 to 120 s, initial voltage 30 to 70 percent. Built-in electronic overload protection. Dimensions 186 mm wide, 390 mm high, 270 mm deep; net weight 10 kg.
- PST85-600-70T
ABB PST85-600-70T soft starter, manufacturer ID 1SFA894008R7020. Main circuit rated 208 to 600 V AC at 50/60 Hz; control supply 100 to 250 V AC, control circuit 24 V DC. In-line connection: 85 A, 45 kW at 400 V and 55 kW at 500 V. Inside delta connection: 147 A, 75 kW at 400 V and 90 kW at 500 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent. Starting capacity 3xIe for 15 s. Ramp time 0 to 120 s or 1 to 120 s, initial voltage 30 to 70 percent, step-down voltage 100 to 30 percent. Dimensions 186 mm wide, 390 mm high, 270 mm deep; net weight 11.2 kg.
- PST85-690-70
ABB PST85-690-70 soft starter, manufacturer ID 1SFA895008R7000, product main type PST85. Main circuit rated operational voltage is 400 to 690 V AC at 50/60 Hz. In-line connection: 85 A rated operational current and 45 kW at 400 V, 55 kW at 500 V, 75 kW at 690 V. Inside delta connection: 147 A and 75 kW at 400 V, 90 kW at 500 V, 132 kW at 690 V. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70 percent. Dimensions 186 x 390 x 270 mm; weight 11.2 kg.
- PST85-690-70T
ABB PST85-690-70T softstarter, manufacturer ID 1SFA895008R7020, product main type PST85. Main circuit rated operational voltage is 400 to 690 V AC at 50/60 Hz. Rated control supply voltage is 100 to 250 V AC; rated control circuit voltage is 24 V DC. In-line connection: 85 A rated operational current and 45 kW at 400 V, 55 kW at 500 V, 75 kW at 690 V. Inside delta connection: 147 A and 75 kW at 400 V, 90 kW at 500 V, 132 kW at 690 V. Adjustable rated motor current is 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 0 to 120 s, initial voltage 30 to 70 percent. Built-in electronic overload protection. Dimensions: 186 mm width, 390 mm height, 270 mm depth; 11.2 kg.