- PST85-600-70
ABB PST85-600-70 softstarter, manufacturer ID 1SFA894008R7000. Main circuit rated operational voltage is 208 to 600 V AC at 50/60 Hz. Rated control supply voltage is 100 to 250 V AC; rated control circuit voltage is 24 V DC. In-line connection ratings are 85 A and 45 kW at 400 V, 55 kW at 500 V. Inside delta connection ratings are 147 A and 75 kW at 400 V, 90 kW at 500 V. Adjustable rated motor current is 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 0 to 120 s, initial voltage 30 to 70 percent. Built-in electronic overload protection. Dimensions 186 mm wide, 390 mm high, 270 mm deep; net weight 10 kg.
- PST85-600-70T
ABB PST85-600-70T soft starter, manufacturer ID 1SFA894008R7020. Main circuit rated 208 to 600 V AC at 50/60 Hz; control supply 100 to 250 V AC, control circuit 24 V DC. In-line connection: 85 A, 45 kW at 400 V and 55 kW at 500 V. Inside delta connection: 147 A, 75 kW at 400 V and 90 kW at 500 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent. Starting capacity 3xIe for 15 s. Ramp time 0 to 120 s or 1 to 120 s, initial voltage 30 to 70 percent, step-down voltage 100 to 30 percent. Dimensions 186 mm wide, 390 mm high, 270 mm deep; net weight 11.2 kg.
- PST85-690-70
ABB PST85-690-70 soft starter, manufacturer ID 1SFA895008R7000, product main type PST85. Main circuit rated operational voltage is 400 to 690 V AC at 50/60 Hz. In-line connection: 85 A rated operational current and 45 kW at 400 V, 55 kW at 500 V, 75 kW at 690 V. Inside delta connection: 147 A and 75 kW at 400 V, 90 kW at 500 V, 132 kW at 690 V. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70 percent. Dimensions 186 x 390 x 270 mm; weight 11.2 kg.
- PST85-690-70T
ABB PST85-690-70T softstarter, manufacturer ID 1SFA895008R7020, product main type PST85. Main circuit rated operational voltage is 400 to 690 V AC at 50/60 Hz. Rated control supply voltage is 100 to 250 V AC; rated control circuit voltage is 24 V DC. In-line connection: 85 A rated operational current and 45 kW at 400 V, 55 kW at 500 V, 75 kW at 690 V. Inside delta connection: 147 A and 75 kW at 400 V, 90 kW at 500 V, 132 kW at 690 V. Adjustable rated motor current is 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 0 to 120 s, initial voltage 30 to 70 percent. Built-in electronic overload protection. Dimensions: 186 mm width, 390 mm height, 270 mm depth; 11.2 kg.
- PSTB1050-600-70
ABB PSTB1050-600-70 softstarter, manufacturer ID 1SFA894020R7000. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz. In-line connection rated operational current 1050 A, with rated operational power 560 kW at 400 V and 730 kW at 500 V. Inside delta connection rated operational current 1810 A, with rated operational power 1000 kW at 400 V and 1250 kW at 500 V. Rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 100 percent. Starting capacity 3xIe for 15 s. Ramp time 0 to 120 s and 1 to 120 s. Initial voltage during start 30 to 70 percent. Dimensions 436 mm width, 515 mm height, 381 mm depth; net weight 60 kg.
- PSTB1050-600-70T
ABB PSTB1050-600-70T softstarter, manufacturer ID 1SFA894020R7020, product main type PSTB1050. Main circuit rated operational voltage is 208 to 600 V AC at 50/60 Hz. Rated operational current is 1050 A in-line and 1810 A in inside-delta connection; rated operational power is 560 kW at 400 V and 730 kW at 500 V in-line, and 1000 kW at 400 V and 1250 kW at 500 V inside delta. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, starting capacity 3xIe for 15 s, ramp time 0 to 120 s, initial voltage 30 to 70 percent. Dimensions 436 x 515 x 381 mm, 60 kg.
- PSTB1050-690-70
ABB PSTB1050-690-70 soft starter, manufacturer ID 1SFA895020R7000, for main circuit 400 to 690 V AC at 50/60 Hz. In-line connection ratings are 1050 A and 560 kW at 400 V, 730 kW at 500 V, and 1000 kW at 690 V. Inside delta connection ratings are 1810 A and 1000 kW at 400 V, 1250 kW at 500 V, and 1700 kW at 690 V. Control supply is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, ramp time 0 to 120 s, current limit 1.5 to 7xIe, starting capacity 3xIe for 15 s. Dimensions 436 x 515 x 381 mm, 60 kg. Main terminals IP00.
- PSTB1050-690-70T
The ABB PSTB1050-690-70T is a softstarter in the PSTB1050 product family, identified by manufacturer ID 1SFA895020R7020. Its main circuit is rated 400 to 690 V AC at 50/60 Hz, with a rated control supply voltage of 100 to 250 V AC and a rated control circuit voltage of 24 V DC. In-line connection ratings are 1050 A and 560 kW at 400 V, 730 kW at 500 V, and 1000 kW at 690 V. Inside delta connection ratings are 1810 A and 1000 kW at 400 V, 1250 kW at 500 V, and 1700 kW at 690 V. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent. Dimensions are 436 mm wide, 515 mm high, and 381 mm deep; net weight is 60 kg.