- PSTB1050-690-70
ABB PSTB1050-690-70 soft starter, manufacturer ID 1SFA895020R7000, for main circuit 400 to 690 V AC at 50/60 Hz. In-line connection ratings are 1050 A and 560 kW at 400 V, 730 kW at 500 V, and 1000 kW at 690 V. Inside delta connection ratings are 1810 A and 1000 kW at 400 V, 1250 kW at 500 V, and 1700 kW at 690 V. Control supply is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, ramp time 0 to 120 s, current limit 1.5 to 7xIe, starting capacity 3xIe for 15 s. Dimensions 436 x 515 x 381 mm, 60 kg. Main terminals IP00.
- PSTB1050-690-70T
The ABB PSTB1050-690-70T is a softstarter in the PSTB1050 product family, identified by manufacturer ID 1SFA895020R7020. Its main circuit is rated 400 to 690 V AC at 50/60 Hz, with a rated control supply voltage of 100 to 250 V AC and a rated control circuit voltage of 24 V DC. In-line connection ratings are 1050 A and 560 kW at 400 V, 730 kW at 500 V, and 1000 kW at 690 V. Inside delta connection ratings are 1810 A and 1000 kW at 400 V, 1250 kW at 500 V, and 1700 kW at 690 V. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent. Dimensions are 436 mm wide, 515 mm high, and 381 mm deep; net weight is 60 kg.
- PSTB370-600-70
ABB PSTB370-600-70 soft starter, manufacturer ID 1SFA894015R7000. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz. Rated operational current 370 A in-line connection, with rated operational power 200 kW at 400 V and 257 kW at 500 V. Inside delta connection ratings are 640 A, 355 kW at 400 V and 450 kW at 500 V. Rated control supply voltage is 100 to 250 V AC; rated control circuit voltage for DC operation is 24 V. Built-in electronic overload protection is included, with adjustable rated motor current 30 to 115 percent. Starting capacity is 3xIe for 15 s. Ramp time 0 to 120 s. Current limit 1.5 to 7xIe. Dimensions 366 x 460 x 361 mm; net weight 31 kg. Main terminals IP00 according to IEC 60529, IEC 60947-1 and EN 60529.
- PSTB370-690-70
ABB PSTB370-690-70 softstarter spare part, manufacturer ID 1SFA895015R7000. Main circuit rated operational voltage 400 to 690 V AC; rated control supply voltage 100 to 250 V AC; control circuit DC operation 24 V; rated frequency 50/60 Hz. In-line connection: rated operational current 370 A, rated operational power 200 kW at 400 V, 257 kW at 500 V, 355 kW at 690 V. Inside delta connection: 640 A, 355 kW at 400 V, 450 kW at 500 V, 600 kW at 690 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 0 to 120 s, initial voltage 30 to 70 percent. Dimensions 366 x 460 x 361 mm; weight 31 kg.
- PSTB470-600-70
ABB PSTB470-600-70 softstarter, product main type PSTB470, manufacturer ID 1SFA894016R7000. Rated operational voltage is 208 to 600 V AC, main circuit, at 50/60 Hz. Rated operational current in-line connection is 470 A, with rated operational power of 250 kW at 400 V and 315 kW at 500 V. Inside delta connection ratings are 814 A, 450 kW at 400 V and 600 kW at 500 V. Rated control supply voltage is 100 to 250 V AC; rated control circuit voltage is 24 V DC. Adjustable rated motor current is 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, current limit 1.5 to 7xIe. Dimensions are 366 mm width, 460 mm height, 361 mm depth, 31 kg.
- PSTB470-600-70T
ABB PSTB470-600-70T soft starter, manufacturer ID 1SFA894016R7020, is a softstarter spare part with a main circuit rated 208 to 600 V AC at 50/60 Hz. In-line connection ratings are 470 A and 250 kW at 400 V, 315 kW at 500 V. Inside-delta connection ratings are 814 A and 450 kW at 400 V, 600 kW at 500 V. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a service factor of 115 percent. Starting capacity is 3xIe for 15 s. Ramp time is 1 to 120 s, initial voltage 30 to 70 percent, and step-down voltage 100 to 30 percent. Dimensions are 366 mm wide, 460 mm high, 361 mm deep; net weight 31 kg.
- PSTB470-690-70
ABB PSTB470-690-70 softstarter, manufacturer ID 1SFA895016R7000. Main circuit rated 400 to 690 V AC, 50/60 Hz, with 24 V DC control circuit. In-line connection: 470 A, 250 kW at 400 V, 315 kW at 500 V, 450 kW at 690 V. Inside-delta connection: 814 A, 450 kW at 400 V, 600 kW at 500 V, 800 kW at 690 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, current limit 1.5 to 7xIe, ramp time 1 to 120 s. Dimensions 366 x 460 x 361 mm, 31 kg. Main terminals IP00 per IEC 60529, IEC 60947-1, EN 60529.
- PSTB470-690-70T
ABB PSTB470-690-70T softstarter, manufacturer ID 1SFA895016R7020, product main type PSTB470. Main circuit rated operational voltage 400 to 690 V AC at 50/60 Hz; rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. In-line connection: rated operational current 470 A, rated operational power 250 kW at 400 V, 315 kW at 500 V, 450 kW at 690 V. Inside delta connection: 814 A, 450 kW at 400 V, 600 kW at 500 V, 800 kW at 690 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, current limit 1.5 to 7xIe. Dimensions 366 x 460 x 361 mm, 31 kg. Main terminals IP00 per IEC 60529, IEC 60947-1, EN 60529.