- PSTB470-690-70
ABB PSTB470-690-70 softstarter, manufacturer ID 1SFA895016R7000. Main circuit rated 400 to 690 V AC, 50/60 Hz, with 24 V DC control circuit. In-line connection: 470 A, 250 kW at 400 V, 315 kW at 500 V, 450 kW at 690 V. Inside-delta connection: 814 A, 450 kW at 400 V, 600 kW at 500 V, 800 kW at 690 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, current limit 1.5 to 7xIe, ramp time 1 to 120 s. Dimensions 366 x 460 x 361 mm, 31 kg. Main terminals IP00 per IEC 60529, IEC 60947-1, EN 60529.
- PSTB470-690-70T
ABB PSTB470-690-70T softstarter, manufacturer ID 1SFA895016R7020, product main type PSTB470. Main circuit rated operational voltage 400 to 690 V AC at 50/60 Hz; rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. In-line connection: rated operational current 470 A, rated operational power 250 kW at 400 V, 315 kW at 500 V, 450 kW at 690 V. Inside delta connection: 814 A, 450 kW at 400 V, 600 kW at 500 V, 800 kW at 690 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, current limit 1.5 to 7xIe. Dimensions 366 x 460 x 361 mm, 31 kg. Main terminals IP00 per IEC 60529, IEC 60947-1, EN 60529.
- PSTB570-690-70
ABB PSTB570-690-70 soft starter, manufacturer ID 1SFA895017R7000, product main type PSTB570. Main circuit rated 400 to 690 V AC at 50/60 Hz, with in-line rated operational current 570 A and inside-delta rated operational current 987 A. In-line rated operational power is 315 kW at 400 V, 400 kW at 500 V, and 560 kW at 690 V; inside-delta power is 540 kW at 400 V, 700 kW at 500 V, and 960 kW at 690 V. Control circuit voltage is DC 24 V. Built-in electronic overload protection is integrated, with adjustable rated motor current 30 to 115 percent and service factor 115 percent. Ramp time is 0 to 120 seconds, initial voltage during start 30 to 70 percent, and current limit 1.5 to 7xIe. Dimensions are 436 mm wide, 515 mm high, 381 mm deep, and 52 kg.
- PSTB570-690-70T
ABB PSTB570-690-70T soft starter, manufacturer ID 1SFA895017R7020. Main circuit rated 400 to 690 V AC at 50/60 Hz; rated control supply voltage 100 to 250 V AC; control circuit DC operation 24 V. In-line connection: 570 A, with rated operational power 315 kW at 400 V, 400 kW at 500 V, and 560 kW at 690 V. Inside delta connection: 987 A, with 540 kW at 400 V, 700 kW at 500 V, and 960 kW at 690 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s. Ramp time 0 to 120 s and 1 to 120 s. Dimensions 436 x 515 x 381 mm, 52 kg. Main terminals IP00 per IEC 60529, IEC 60947-1, EN 60529.
- PSTB720-600-70
ABB PSTB720-600-70 softstarter, manufacturer ID 1SFA894018R7000. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz. Rated operational current is 720 A in-line and 1247 A inside delta. Rated operational power is 400 kW at 400 V and 500 kW at 500 V in-line, and 710 kW at 400 V and 880 kW at 500 V inside delta. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection is included, with adjustable rated motor current 30 to 115 percent and service factor 115 percent. Starting capacity is 3xIe for 15 s. Ramp time is 0 to 120 s, initial voltage 30 to 70 percent, step-down voltage 100 to 30 percent. Dimensions are 436 mm wide, 515 mm high, 381 mm deep; net weight 55 kg.
- PSTB720-600-70T
ABB PSTB720-600-70T softstarter, manufacturer ID 1SFA894018R7020. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz. In-line connection rated operational current 720 A, with rated operational power 400 kW at 400 V and 500 kW at 500 V. Inside delta connection rated operational current 1247 A, with rated operational power 710 kW at 400 V and 880 kW at 500 V. Rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent. Starting capacity 3xIe for 15 s. Ramp time 1 to 120 s. Initial voltage during start 30 to 70 percent. Dimensions 436 mm width, 515 mm height, 381 mm depth; net weight 52 kg.
- PSTB720-690-70
ABB softstarter PSTB720-690-70, product main type PSTB720, manufacturer ID 1SFA895018R7000. Main circuit rated operational voltage 400 to 690 V AC at 50/60 Hz. In-line connection: rated operational current 720 A, rated operational power 400 kW at 400 V, 500 kW at 500 V, 710 kW at 690 V. Inside delta connection: 1247 A, 710 kW at 400 V, 880 kW at 500 V, 1200 kW at 690 V. Rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. Built-in electronic overload protection with adjustable rated motor current 30 to 115 percent. Starting capacity 3xIe for 15 s. Ramp time 0 to 120 s. Current limit 1.5 to 7xIe. Net dimensions 436 x 515 x 381 mm, 55 kg.
- PSTB840-600-70T
ABB PSTB840-600-70T softstarter, manufacturer ID 1SFA894019R7020, product main type PSTB840. Main circuit rated operational voltage is 208 to 600 V AC at 50/60 Hz. Rated operational current is 840 A in-line connection and 1455 A inside delta connection. Rated operational power is 450 kW at 400 V and 600 kW at 500 V in-line, and 800 kW at 400 V and 1000 kW at 500 V inside delta. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a service factor of 115 percent. Starting capacity is 3xIe for 15 s. Ramp time is 0 to 120 s, initial voltage 30 to 70 percent. Dimensions are 436 mm width, 515 mm height, 381 mm depth; net weight 60 kg.