- PSTB470-690-70T
ABB PSTB470-690-70T softstarter, manufacturer ID 1SFA895016R7020, product main type PSTB470. Main circuit rated operational voltage 400 to 690 V AC at 50/60 Hz; rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. In-line connection: rated operational current 470 A, rated operational power 250 kW at 400 V, 315 kW at 500 V, 450 kW at 690 V. Inside delta connection: 814 A, 450 kW at 400 V, 600 kW at 500 V, 800 kW at 690 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, current limit 1.5 to 7xIe. Dimensions 366 x 460 x 361 mm, 31 kg. Main terminals IP00 per IEC 60529, IEC 60947-1, EN 60529.
- PSTB570-690-70
ABB PSTB570-690-70 soft starter, manufacturer ID 1SFA895017R7000, product main type PSTB570. Main circuit rated 400 to 690 V AC at 50/60 Hz, with in-line rated operational current 570 A and inside-delta rated operational current 987 A. In-line rated operational power is 315 kW at 400 V, 400 kW at 500 V, and 560 kW at 690 V; inside-delta power is 540 kW at 400 V, 700 kW at 500 V, and 960 kW at 690 V. Control circuit voltage is DC 24 V. Built-in electronic overload protection is integrated, with adjustable rated motor current 30 to 115 percent and service factor 115 percent. Ramp time is 0 to 120 seconds, initial voltage during start 30 to 70 percent, and current limit 1.5 to 7xIe. Dimensions are 436 mm wide, 515 mm high, 381 mm deep, and 52 kg.
- PSTB570-690-70T
ABB PSTB570-690-70T soft starter, manufacturer ID 1SFA895017R7020. Main circuit rated 400 to 690 V AC at 50/60 Hz; rated control supply voltage 100 to 250 V AC; control circuit DC operation 24 V. In-line connection: 570 A, with rated operational power 315 kW at 400 V, 400 kW at 500 V, and 560 kW at 690 V. Inside delta connection: 987 A, with 540 kW at 400 V, 700 kW at 500 V, and 960 kW at 690 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s. Ramp time 0 to 120 s and 1 to 120 s. Dimensions 436 x 515 x 381 mm, 52 kg. Main terminals IP00 per IEC 60529, IEC 60947-1, EN 60529.
- PSTB720-600-70
ABB PSTB720-600-70 softstarter, manufacturer ID 1SFA894018R7000. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz. Rated operational current is 720 A in-line and 1247 A inside delta. Rated operational power is 400 kW at 400 V and 500 kW at 500 V in-line, and 710 kW at 400 V and 880 kW at 500 V inside delta. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection is included, with adjustable rated motor current 30 to 115 percent and service factor 115 percent. Starting capacity is 3xIe for 15 s. Ramp time is 0 to 120 s, initial voltage 30 to 70 percent, step-down voltage 100 to 30 percent. Dimensions are 436 mm wide, 515 mm high, 381 mm deep; net weight 55 kg.
- PSTB720-600-70T
ABB PSTB720-600-70T softstarter, manufacturer ID 1SFA894018R7020. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz. In-line connection rated operational current 720 A, with rated operational power 400 kW at 400 V and 500 kW at 500 V. Inside delta connection rated operational current 1247 A, with rated operational power 710 kW at 400 V and 880 kW at 500 V. Rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent. Starting capacity 3xIe for 15 s. Ramp time 1 to 120 s. Initial voltage during start 30 to 70 percent. Dimensions 436 mm width, 515 mm height, 381 mm depth; net weight 52 kg.
- PSTB720-690-70
ABB softstarter PSTB720-690-70, product main type PSTB720, manufacturer ID 1SFA895018R7000. Main circuit rated operational voltage 400 to 690 V AC at 50/60 Hz. In-line connection: rated operational current 720 A, rated operational power 400 kW at 400 V, 500 kW at 500 V, 710 kW at 690 V. Inside delta connection: 1247 A, 710 kW at 400 V, 880 kW at 500 V, 1200 kW at 690 V. Rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. Built-in electronic overload protection with adjustable rated motor current 30 to 115 percent. Starting capacity 3xIe for 15 s. Ramp time 0 to 120 s. Current limit 1.5 to 7xIe. Net dimensions 436 x 515 x 381 mm, 55 kg.
- PSTB840-600-70T
ABB PSTB840-600-70T softstarter, manufacturer ID 1SFA894019R7020, product main type PSTB840. Main circuit rated operational voltage is 208 to 600 V AC at 50/60 Hz. Rated operational current is 840 A in-line connection and 1455 A inside delta connection. Rated operational power is 450 kW at 400 V and 600 kW at 500 V in-line, and 800 kW at 400 V and 1000 kW at 500 V inside delta. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a service factor of 115 percent. Starting capacity is 3xIe for 15 s. Ramp time is 0 to 120 s, initial voltage 30 to 70 percent. Dimensions are 436 mm width, 515 mm height, 381 mm depth; net weight 60 kg.
- PSTBH-1
ABB PSTBH-1 spare part for PST softstarters, identified by manufacturer ID 1SFA899031R1001. It is classified as an accessory/spare part for low-voltage switch technology under ETIM 8 and ETIM 9 (EC002498), and as a protection switch disconnector housing under ETIM 7 (EC000249). Dimensions are 200 mm width, 100 mm depth or length, and 200 mm height, with a net weight of 0.7 kg. The part is suitable for the PST product class of softstarters. eClass V11.0 classification is 27371392. No electrical ratings, voltage ranges, current ratings, communication protocols, or certifications are stated for this item.