- PST175-690-70
ABB PST175-690-70 softstarter, manufacturer ID 1SFA895011R7000. Rated operational voltage main circuit 400 to 690 V AC at 50/60 Hz; rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. In-line connection: 175 A, 90 kW at 400 V, 110 kW at 500 V, 160 kW at 690 V. Inside delta connection: 300 A, 160 kW at 400 V, 200 kW at 500 V, 257 kW at 690 V. Adjustable rated motor current 30 to 115%, service factor 115%, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70%. Built-in electronic overload protection. Dimensions 360 x 420 x 270 mm, 21.5 kg. Main terminals IP00 per IEC 60529, IEC 60947-1, EN 60529. Ambient operation 0 to +50 °C.
- PST175-690-70T
ABB PST175-690-70T softstarter, manufacturer ID 1SFA895011R7020. Main circuit rated operational voltage 400 to 690 V AC at 50/60 Hz. Rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. In-line connection: 175 A rated operational current, with rated operational power of 90 kW at 400 V, 110 kW at 500 V, and 160 kW at 690 V. Inside delta connection: 300 A, with 160 kW at 400 V, 200 kW at 500 V, and 257 kW at 690 V. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70 percent. Coated PCB assembly. Dimensions 360 x 420 x 270 mm; net weight 21.5 kg.
- PST210-600-70
ABB PST210-600-70 soft starter, manufacturer ID 1SFA894012R7000. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz. Rated operational current in-line connection 210 A; inside delta connection 360 A. Rated operational power in-line connection 110 kW at 400 V and 132 kW at 500 V; inside delta connection 184 kW at 400 V and 250 kW at 500 V. Rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent. Starting capacity 3xIe for 15 s. Ramp time 0 to 120 s. Current limit 1.5 to 7xIe. Dimensions 360 x 420 x 270 mm; net weight 21.5 kg. Main terminals IP00 per IEC 60529, IEC 60947-1, EN 60529. Ambient operating temperature 0 to +50 degrees C.
- PST210-690-70
ABB PST210-690-70 soft starter, manufacturer ID 1SFA895012R7000. Main circuit rated operational voltage 400 to 690 V AC at 50/60 Hz. In-line connection: rated operational current 210 A, rated operational power 110 kW at 400 V, 132 kW at 500 V, and 184 kW at 690 V. Inside delta connection: 360 A, with 184 kW at 400 V, 250 kW at 500 V, and 315 kW at 690 V. Control supply voltage 100 to 250 V AC; control circuit voltage 24 V DC. Built-in electronic overload protection, adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s, ramp time 1 to 120 s, initial voltage 30 to 70 percent. Dimensions 360 x 420 x 270 mm; net weight 20 kg.
- PST210-690-70T
Product identification: ABB PST210-690-70T. ABB PST210 soft starter, manufacturer ID 1SFA895012R7020, for in-line or inside-delta motor starting. In-line ratings: 210 A, 110 kW at 400 V, 132 kW at 500 V, and 184 kW at 690 V. Inside-delta ratings: 360 A, 184 kW at 400 V, 250 kW at 500 V, and 315 kW at 690 V. Main circuit voltage is 400 to 690 V AC at 50/60 Hz. Control supply is 100 to 250 V AC; control circuit is 24 V DC. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a 115 percent service factor. Starting capacity is 3xIe for 15 s. Ramp time is 1 to 120 s; initial voltage is 30 to 70 percent. Dimensions are 360 mm wide, 420 mm high, and 270 mm deep; net weight is 21.5 kg.
- PST250-600-70
ABB PST250-600-70 softstarter, manufacturer ID 1SFA894013R7000. Main circuit rated operational voltage 208 to 600 V AC at 50/60 Hz; rated control supply voltage 100 to 250 V AC; rated control circuit voltage 24 V DC. In-line connection: rated operational current 250 A, rated operational power 132 kW at 400 V and 160 kW at 500 V. Inside delta connection: 430 A, 220 kW at 400 V and 295 kW at 500 V. Adjustable rated motor current 30 to 115 percent, service factor 115 percent, starting capacity 3xIe for 15 s. Ramp time 1 to 120 s, initial voltage 30 to 70 percent, step-down voltage 100 to 30 percent. Built-in electronic overload protection. Dimensions 360 x 420 x 270 mm, 23 kg.
- PST250-690-70
ABB PST250-690-70 softstarter, manufacturer ID 1SFA895013R7000, product main type PST250. Main circuit rated operational voltage is 400 to 690 V AC at 50/60 Hz. Rated operational current in in-line connection is 250 A, with rated operational power of 132 kW at 400 V, 160 kW at 500 V, and 220 kW at 690 V. Inside delta connection ratings are 430 A, with 220 kW at 400 V, 295 kW at 500 V, and 400 kW at 690 V. Control supply voltage is 100 to 250 V AC; control circuit voltage is 24 V DC. Built-in electronic overload protection is included, with adjustable rated motor current from 30 to 115 percent and a 115 percent service factor. Starting capacity is 3xIe for 15 s. Ramp time is 0 to 120 s. Dimensions are 360 mm width, 420 mm height, and 270 mm depth; net weight is 23 kg.
- PST250-690-70T
ABB PST250-690-70T softstarter, manufacturer ID 1SFA895013R7020, is a spare part in the PST250 product main type. It measures 360 mm wide, 420 mm high, and 270 mm deep, weighing 23 kg. The main circuit is rated 400 to 690 V AC at 50/60 Hz, with control supply voltage 100 to 250 V AC and control circuit voltage 24 V DC. In-line connection ratings are 250 A and 132 kW at 400 V, 160 kW at 500 V, and 220 kW at 690 V. Inside-delta ratings are 430 A and 220 kW at 400 V, 295 kW at 500 V, and 400 kW at 690 V. Built-in electronic overload protection is included, with adjustable rated motor current 30 to 115 percent and starting capacity 3xIe for 15 s.