- AFC40-22-00-42
ABB AFC40-22-00-42 is a 4-pole AC contactor, manufacturer ID 1SBL341501R4200, with two normally open and two normally closed main contacts and no auxiliary contacts. Main circuit rated operational voltage is 690 V at 50/60 Hz. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. AC-3 ratings include 40 A at 415 V and 60 °C, and 25 A at 690 V and 60 °C. Rated operational power AC-3 is 22 kW at 415 V and 11 kW at 220/230/240 V. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC40-22-00-51
ABB AFC40-22-00-51 AC contactor, manufacturer ID 1SBL341501R5100, for switching three-phase motors and power circuits. It has 2 normally open and 2 normally closed main contacts, with no auxiliary contacts. Main circuit rated operational voltage is 690 V at 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Dimensions are 70 mm wide, 119.5 mm deep, 113.5 mm high; weight 1.18 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC40-22-00-80
The ABB AFC40-22-00-80 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. The coil is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Main circuit rated operational voltage is 690 V; rated operational current AC-3 is 40 A at 415 V and 40 A at 440 V, both at 60 °C. Screw terminals are used. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high, with a net weight of 1.18 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-22-00-81
ABB AFC40-22-00-81 AC contactor, manufacturer ID 1SBL341501R8100. Four-pole device with 2 main contacts NO and 2 main contacts NC; no auxiliary contacts. Rated operational voltage of main circuit is 690 V; rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 690 V and 60 °C, and 50 A at 690 V and 70 °C. AC-3 rating is 40 A at 415 V and 60 °C, with rated operational power 22 kW at 415 V. Coil is rated 24 V at 50 Hz and 24 V at 60 Hz. Screw terminals; dimensions 70 mm wide, 119.5 mm deep, 113.5 mm high; net weight 1.18 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC40-22-00-84
The ABB AFC40-22-00-84 is a 4-pole AC contactor with 2 NO and 2 NC main contacts and no auxiliary contacts. It is rated 690 V in the main circuit and carries 70 A at 40 °C, 60 A at 60 °C, and 50 A at 70 °C under AC-1. AC-3 ratings include 40 A at 415 V and 25 A at 690 V, with 22 kW at 415 V. The coil operates at 110 V, 50 Hz or 110 to 120 V, 60 Hz. Screw terminals accept main-circuit conductors from 4 to 35 mm². Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high; weight is 1.18 kg. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-22-00-85
The ABB AFC40-22-00-85 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and an AC-3 operational current of 40 A at 415 V, 60 °C, corresponding to 22 kW. The control circuit is rated 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. It measures 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1. Mounting is on TH35-15 DIN rail or by two M4 or M6 screws placed diagonally.
- AFC40-22-00-86
ABB AFC40-22-00-86 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 105 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 70 A at 40 °C, 60 A at 60 °C, and 50 A at 70 °C, all at 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-22-00-88
ABB AFC40-22-00-88 is a 4-pole AC contactor with 2 main contacts NO and 2 main contacts NC, and no auxiliary contacts. The coil is rated 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Rated operational voltage of the main circuit is 690 V. Rated operational current AC-3 is 40 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, and 25 A at 690 V at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high, with a net weight of 1.18 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.