- AFC40-22-00-84
The ABB AFC40-22-00-84 is a 4-pole AC contactor with 2 NO and 2 NC main contacts and no auxiliary contacts. It is rated 690 V in the main circuit and carries 70 A at 40 °C, 60 A at 60 °C, and 50 A at 70 °C under AC-1. AC-3 ratings include 40 A at 415 V and 25 A at 690 V, with 22 kW at 415 V. The coil operates at 110 V, 50 Hz or 110 to 120 V, 60 Hz. Screw terminals accept main-circuit conductors from 4 to 35 mm². Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high; weight is 1.18 kg. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-22-00-85
The ABB AFC40-22-00-85 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and an AC-3 operational current of 40 A at 415 V, 60 °C, corresponding to 22 kW. The control circuit is rated 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. It measures 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1. Mounting is on TH35-15 DIN rail or by two M4 or M6 screws placed diagonally.
- AFC40-22-00-86
ABB AFC40-22-00-86 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 105 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 70 A at 40 °C, 60 A at 60 °C, and 50 A at 70 °C, all at 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-22-00-88
ABB AFC40-22-00-88 is a 4-pole AC contactor with 2 main contacts NO and 2 main contacts NC, and no auxiliary contacts. The coil is rated 230 to 240 V at 50 Hz and 240 to 260 V at 60 Hz. Rated operational voltage of the main circuit is 690 V. Rated operational current AC-3 is 40 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, and 25 A at 690 V at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high, with a net weight of 1.18 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-30-00-34
The ABB AFC40-30-00-34 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. Rated operational current AC-3 is 40 A at 415 V and 60 °C, and 25 A at 690 V and 60 °C. Rated operational power AC-3 is 22 kW at 415 V and 18.5 kW at 380/400 V. Dimensions are 55 mm wide, 119.5 mm deep, and 111 mm high, with a net weight of 0.98 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC40-30-00-42
ABB AFC40-30-00-42 is a 4-pole AC contactor, manufacturer ID 1SBL341001R4200. It has 3 main contacts NO and no auxiliary contacts. Main circuit rated operational voltage is 690 V, with 50/60 Hz rated frequency for main and auxiliary circuits. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. AC-3 ratings include 40 A at 415 V and 60 °C, and 25 A at 690 V and 60 °C. Rated operational power AC-3 is 22 kW at 415 V and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Dimensions are 55 mm wide, 119.5 mm deep, 111 mm high, 0.98 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-00-51
ABB AFC40-30-00-51 is a non-reversing AC contactor for 3-phase motors and non-inductive loads. It has 3 main contacts NO and no auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C; 35 A at 500 V; 25 A at 690 V. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V; 18.5 kW at 380/400 V; 11 kW at 220/230/240 V. Dimensions are 55 mm wide, 119.5 mm deep, 111 mm high; net weight 0.98 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-00-80
ABB AFC40-30-00-80 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, weighing 0.98 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 40 A at 415 V and 60 °C, 35 A at 500 V, and 25 A at 690 V. Rated operational power AC-3 is 22 kW at 415 V and 18.5 kW at 380/400 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.