- AFC40-30-00-34
The ABB AFC40-30-00-34 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. Rated operational current AC-3 is 40 A at 415 V and 60 °C, and 25 A at 690 V and 60 °C. Rated operational power AC-3 is 22 kW at 415 V and 18.5 kW at 380/400 V. Dimensions are 55 mm wide, 119.5 mm deep, and 111 mm high, with a net weight of 0.98 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC40-30-00-42
ABB AFC40-30-00-42 is a 4-pole AC contactor, manufacturer ID 1SBL341001R4200. It has 3 main contacts NO and no auxiliary contacts. Main circuit rated operational voltage is 690 V, with 50/60 Hz rated frequency for main and auxiliary circuits. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. AC-3 ratings include 40 A at 415 V and 60 °C, and 25 A at 690 V and 60 °C. Rated operational power AC-3 is 22 kW at 415 V and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Dimensions are 55 mm wide, 119.5 mm deep, 111 mm high, 0.98 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-00-51
ABB AFC40-30-00-51 is a non-reversing AC contactor for 3-phase motors and non-inductive loads. It has 3 main contacts NO and no auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C; 35 A at 500 V; 25 A at 690 V. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V; 18.5 kW at 380/400 V; 11 kW at 220/230/240 V. Dimensions are 55 mm wide, 119.5 mm deep, 111 mm high; net weight 0.98 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-00-80
ABB AFC40-30-00-80 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, weighing 0.98 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 40 A at 415 V and 60 °C, 35 A at 500 V, and 25 A at 690 V. Rated operational power AC-3 is 22 kW at 415 V and 18.5 kW at 380/400 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC40-30-00-81
The ABB AFC40-30-00-81 is a 3-pole AC contactor with 3 NO main contacts and no auxiliary contacts, using screw terminals. The main circuit is rated 690 V, with AC-3 ratings of 40 A at 415 V and 25 A at 690 V, both at 60 °C, and AC-3 power of 18.5 kW at 380/400 V and 22 kW at 415 V. The coil is rated 24 V at 50 Hz and 60 Hz. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, and weighs 0.98 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL341001R8100.
- AFC40-30-00-84
ABB AFC40-30-00-84 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, weighing 0.98 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 40 A at 415 V, 440 V, and 220/230/240 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-00-85
The ABB AFC40-30-00-85 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, and weighs 0.98 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 40 A at 380/400 V and 415 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 22 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-00-88
ABB AFC40-30-00-88 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. The main circuit is rated 690 V. Per IEC 60947-4-1, conventional free-air thermal current Ith is 105 A at 40 °C for open contactors. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. Rated operational current AC-3 is 40 A at 380/400 V and 60 °C, and 25 A at 690 V and 60 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 22 kW at 415 V. Dimensions are 55 mm wide, 119.5 mm deep, 111 mm high; weight 0.98 kg. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.