- AFC40-30-00-84
ABB AFC40-30-00-84 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, weighing 0.98 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 40 A at 415 V, 440 V, and 220/230/240 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-00-85
The ABB AFC40-30-00-85 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, and weighs 0.98 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 40 A at 380/400 V and 415 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 22 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-00-88
ABB AFC40-30-00-88 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. The main circuit is rated 690 V. Per IEC 60947-4-1, conventional free-air thermal current Ith is 105 A at 40 °C for open contactors. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. Rated operational current AC-3 is 40 A at 380/400 V and 60 °C, and 25 A at 690 V and 60 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 22 kW at 415 V. Dimensions are 55 mm wide, 119.5 mm deep, 111 mm high; weight 0.98 kg. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AFC40-30-11-42
ABB AC contactor AFC40-30-11-42, manufacturer ID 1SBL341001R4211. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Dimensions are 67 mm wide, 119.5 mm deep, and 111 mm high, with a net weight of 1.02 kg. The main circuit is rated 690 V at 50/60 Hz; the auxiliary circuit is rated 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V and 440 V, 35 A at 500 V, and 25 A at 690 V, at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-11-51
ABB AFC40-30-11-51 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V and 60 °C, 35 A at 500 V, and 25 A at 690 V. Rated operational power AC-3 is 18.5 kW at 380/400 V and 22 kW at 415 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC40-30-11-80
The ABB AFC40-30-11-80 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 690 V in the main circuit and carries a rated operational current AC-3 of 40 A at 380/400 V and 60 °C, corresponding to 18.5 kW at 380/400 V. The control circuit is rated 220 to 230 V AC at 50 Hz or 230 to 240 V AC at 60 Hz. Screw terminals are provided. It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1. Dimensions are 67 mm wide, 119.5 mm deep, and 111 mm high, with a net weight of 1.02 kg.
- AFC40-30-11-81
ABB AFC40-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V. Rated operational current AC-3 is 40 A at 415 V and 440 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Dimensions are 67 mm wide, 119.5 mm deep, and 111 mm high, with a net weight of 1.02 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-11-84
ABB AFC40-30-11-84 is a 3-pole AC contactor with three normally open main contacts and one auxiliary NO plus one auxiliary NC contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, weighing 1.02 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 40 A at 415 V and 60 °C, 35 A at 500 V, and 25 A at 690 V. AC-3 rated power is 22 kW at 415 V and 18.5 kW at 380/400 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.