- AFC40-30-11-51
ABB AFC40-30-11-51 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V and 60 °C, 35 A at 500 V, and 25 A at 690 V. Rated operational power AC-3 is 18.5 kW at 380/400 V and 22 kW at 415 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC40-30-11-80
The ABB AFC40-30-11-80 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 690 V in the main circuit and carries a rated operational current AC-3 of 40 A at 380/400 V and 60 °C, corresponding to 18.5 kW at 380/400 V. The control circuit is rated 220 to 230 V AC at 50 Hz or 230 to 240 V AC at 60 Hz. Screw terminals are provided. It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1. Dimensions are 67 mm wide, 119.5 mm deep, and 111 mm high, with a net weight of 1.02 kg.
- AFC40-30-11-81
ABB AFC40-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V. Rated operational current AC-3 is 40 A at 415 V and 440 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Dimensions are 67 mm wide, 119.5 mm deep, and 111 mm high, with a net weight of 1.02 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-11-84
ABB AFC40-30-11-84 is a 3-pole AC contactor with three normally open main contacts and one auxiliary NO plus one auxiliary NC contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, weighing 1.02 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 40 A at 415 V and 60 °C, 35 A at 500 V, and 25 A at 690 V. AC-3 rated power is 22 kW at 415 V and 18.5 kW at 380/400 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-11-85
ABB AFC40-30-11-85 is a 3-pole AC contactor, manufacturer ID 1SBL341001R8511. It has 3 main contacts NO, 0 main contacts NC, and 1 auxiliary contact NO plus 1 auxiliary contact NC. Rated operational voltage for the main circuit is 690 V. Rated operational current AC-3 is 40 A at 380/400 V, 415 V, 440 V, 220/230/240 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 22 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 67 mm width, 119.5 mm depth, 111 mm height, 1.02 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-11-86
ABB AC contactor AFC40-30-11-86 (manufacturer ID 1SBL341001R8611) has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Main circuit rated operational voltage is 690 V at 50/60 Hz. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. Rated operational current AC-3 is 40 A at 415 V and 60 °C, 35 A at 500 V, and 25 A at 690 V. Rated operational power AC-3 is 22 kW at 415 V and 18.5 kW at 380/400 V. Dimensions are 67 mm width, 119.5 mm depth, 111 mm height, 1.02 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-30-11-88
ABB AFC40-30-11-88 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Screw terminals are used. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 40 A at 415 V and 60 °C, and 25 A at 690 V and 60 °C. AC-3 power ratings include 18.5 kW at 380/400 V and 22 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC40-40-00-34
ABB AFC40-40-00-34 AC contactor, manufacturer ID 1SBL341201R3400. Four normally open main contacts, no normally closed main contacts, and no auxiliary contacts. Main circuit rated operational voltage 690 V; rated frequency 50/60 Hz for main and auxiliary circuits. Conventional free-air thermal current per IEC 60947-4-1 for open contactors at 40 °C is 105 A. Rated operational current AC-1 at 690 V is 70 A at 40 °C, 60 A at 60 °C, and 50 A at 70 °C. Rated operational current AC-3 at 415 V and 440 V is 40 A at 60 °C. Rated insulation voltage 690 V per IEC 60947-4-1 and VDE 0110 Gr. C, 600 V per UL/CSA. Net dimensions 70 mm width, 119.5 mm depth, 113.5 mm height; weight 1.18 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.