- AFC40-40-00-51
ABB AC contactor AFC40-40-00-51, manufacturer ID 1SBL341201R5100. It has four normally open main contacts and no normally closed main or auxiliary contacts. Main circuit rated operational voltage is 690 V; rated frequency is 50/60 Hz for main and auxiliary circuits. Rated operational current AC-3 is 40 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Dimensions are 70 mm width, 119.5 mm depth, 113.5 mm height; weight 1.18 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC40-40-00-80
The ABB AFC40-40-00-80 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 690 V in the main circuit and carries 70 A at 40 °C, 60 A at 60 °C, and 50 A at 70 °C under AC-1 at 690 V. AC-3 ratings include 40 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Coil voltage is 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Screw terminals are provided. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high, with a net weight of 1.18 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-40-00-81
The ABB AFC40-40-00-81 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. Its coil is rated for 24 V at 50 Hz and 24 V at 60 Hz. Rated operational current is 70 A at 690 V and 40 °C in AC-1, and 40 A at 380/400 V and 60 °C in AC-3. Rated operational voltage for the main circuit is 690 V. The contactor uses screw terminals and measures 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. It is declared to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-40-00-84
ABB AFC40-40-00-84 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. The coil is rated 110 V at 50 Hz and 110 to 120 V at 60 Hz. Rated operational voltage for the main circuit is 690 V; rated operational current AC-3 is 40 A at 415 V, 440 V, and 380/400 V at 60 °C, and 25 A at 690 V at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high, with a net weight of 1.18 kg. Screw terminals accept main-circuit conductors from 4 to 35 mm². Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-40-00-85
The ABB AFC40-40-00-85 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 40 A in AC-3 at 415 V and 60 °C, with rated operational power of 22 kW at 415 V and a main circuit rated operational voltage of 690 V. Coil control voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. The contactor uses screw terminals, mounts on TH35-15 DIN rail to IEC 60715, and measures 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-40-00-86
ABB AFC40-40-00-86 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. The main circuit is rated 690 V, with 50/60 Hz operation. Conventional free-air thermal current is 105 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. AC-3 ratings include 40 A at 415 V and 25 A at 690 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC40-40-00-88
The ABB AFC40-40-00-88 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. Its coil operates at 230 to 240 V 50 Hz or 240 to 260 V 60 Hz. Rated operational voltage for the main circuit is 690 V, with AC-1 rated operational current of 70 A at 40 °C and 60 A at 60 °C. AC-3 ratings include 40 A at 415 V and 25 A at 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C. It uses screw terminals, mounts on TH35-15 DIN rail per IEC 60715, and measures 70 mm wide, 119.5 mm deep, and 113.5 mm high. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC52-30-00-34
The ABB AFC52-30-00-34 is a 3-pole AC contactor with screw terminals and three normally open main contacts. It is rated 690 V in the main circuit at 50/60 Hz, with AC-3 ratings of 53 A at 380/400 V and 22 kW at 380/400 V, both at 60 °C. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C. Coil control voltages are 175 V at 50 Hz and 208 V at 60 Hz. Dimensions are 55 mm wide, 119.5 mm deep, and 111 mm high, weighing 0.98 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.