- AFC40-40-00-84
ABB AFC40-40-00-84 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. The coil is rated 110 V at 50 Hz and 110 to 120 V at 60 Hz. Rated operational voltage for the main circuit is 690 V; rated operational current AC-3 is 40 A at 415 V, 440 V, and 380/400 V at 60 °C, and 25 A at 690 V at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high, with a net weight of 1.18 kg. Screw terminals accept main-circuit conductors from 4 to 35 mm². Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-40-00-85
The ABB AFC40-40-00-85 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 40 A in AC-3 at 415 V and 60 °C, with rated operational power of 22 kW at 415 V and a main circuit rated operational voltage of 690 V. Coil control voltage is 380 to 400 V at 50 Hz and 400 to 415 V at 60 Hz. The contactor uses screw terminals, mounts on TH35-15 DIN rail to IEC 60715, and measures 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-40-00-86
ABB AFC40-40-00-86 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. The main circuit is rated 690 V, with 50/60 Hz operation. Conventional free-air thermal current is 105 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. AC-3 ratings include 40 A at 415 V and 25 A at 690 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC40-40-00-88
The ABB AFC40-40-00-88 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. Its coil operates at 230 to 240 V 50 Hz or 240 to 260 V 60 Hz. Rated operational voltage for the main circuit is 690 V, with AC-1 rated operational current of 70 A at 40 °C and 60 A at 60 °C. AC-3 ratings include 40 A at 415 V and 25 A at 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C. It uses screw terminals, mounts on TH35-15 DIN rail per IEC 60715, and measures 70 mm wide, 119.5 mm deep, and 113.5 mm high. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC52-30-00-34
The ABB AFC52-30-00-34 is a 3-pole AC contactor with screw terminals and three normally open main contacts. It is rated 690 V in the main circuit at 50/60 Hz, with AC-3 ratings of 53 A at 380/400 V and 22 kW at 380/400 V, both at 60 °C. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C. Coil control voltages are 175 V at 50 Hz and 208 V at 60 Hz. Dimensions are 55 mm wide, 119.5 mm deep, and 111 mm high, weighing 0.98 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC52-30-00-42
ABB AFC52-30-00-42 is a 3-pole AC contactor, manufacturer ID 1SBL361001R4200. It has three normally open main contacts and no auxiliary contacts. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 53 A at 380/400 V and 60 °C, and rated operational power of 22 kW at 380/400 V. Dimensions are 55 mm wide, 119.5 mm deep, and 111 mm high, weighing 0.98 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC52-30-00-80
The ABB AFC52-30-00-80 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its coil operates at 220-230 V 50 Hz and 230-240 V 60 Hz. Rated operational voltage for the main circuit is 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 53 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, and 35 A at 690 V at 60 °C. Dimensions are 55 mm wide, 119.5 mm deep, and 111 mm high, with a net weight of 0.98 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC52-30-00-81
ABB AFC52-30-00-81 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, and weighs 0.98 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 53 A at 380/400 V and 60 °C, with rated operational power AC-3 of 22 kW at 380/400 V. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.