ABB AFC40-40-00-86 AC contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB AFC40-40-00-86?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB AFC40-40-00-86 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
AFC40-40-00-86
Material Number
1SBL341201R8600
Manufacturer
ABB
Product ID
88394

Get a Free Quote

Request pricing and availability for AFC40-40-00-86.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
1.18 kg
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 70 A (690 V) 60 °C 60 A (690 V) 70 °C 50 A
Rated Operational Power AC-3 (Pe)
(415 V) 22 kW (440 V) 22 kW (500 V) 22 kW (690 V) 22 kW (380 / 400 V) 18.5 kW (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
See all specifications

Product Highlights

  1. Main Contacts: 4 normally open (NO) main contacts with no normally closed or auxiliary contacts
  2. Rated Operational Voltage: Main circuit rated 690 V with 50/60 Hz rated frequency for both main and auxiliary circuits
  3. Current Ratings: Conventional free-air thermal current 105 A at 40 °C and AC-1 rated operational current 70 A at 40 °C, 60 A at 60 °C, and 50 A at 70 °C at 690 V
  4. AC-3 Ratings: Rated operational current 40 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 35 A at 500 V, and 25 A at 690 V, with rated operational power up to 22 kW
  5. Coil and Operating Time: Rated control circuit voltage 400 to 415 V at 50 Hz and 415 to 440 V at 60 Hz, with operate times from 4 to 105 ms depending on contact transition
  6. Mounting and Connection: DIN rail mounting per IEC 60715 or screw mounting with 2 x M4 or 2 x M6 screws, screw terminals with main circuit connecting capacity 6 to 35 mm² rigid and 4 to 35 mm² flexible
  7. Ambient and Altitude: Operating ambient air temperature -40 to 70 °C and maximum operating altitude 3000 m without derating
  8. Standards and Protection: Complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1, with IP20 auxiliary and coil terminals and IP10 main terminals
AFC40-40-00-86

Product Information

Technical Specifications

Specifications for AFC40-40-00-86

ParameterValue
Product Net Width70 mm
Product Net Depth / Length119.5 mm
Product Net Height113.5 mm
Product Net Weight1.18 kg
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 5060 Hz Main Circuit 5060 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 70 A (690 V) 60 °C 60 A (690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 40 A (440 V) 60 °C 40 A (500 V) 60 °C 35 A (690 V) 60 °C 25 A (380400 V) 60 °C 40 A (220230240 V) 60 °C 40 A
Rated Operational Power AC-3 (Pe)(415 V) 22 kW (440 V) 22 kW (500 V) 22 kW (690 V) 22 kW (380400 V) 18.5 kW (220230240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
ParameterValue
Rated Control Circuit Voltage (Uc)50 Hz 400 ... 415 V 60 Hz 415 ... 440 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 20 V·A Average Pull-in Value 50 Hz 150 V·A Average Pull-in Value 60 Hz 151 V·A
Operate TimeBetween Coil De-energization and NC Contact Closing 19 ... 105 ms Between Coil De-energization and NO Contact Opening 4 ... 14 ms Between Coil Energization and NC Contact Opening 38 ... 95 ms Between Coil Energization and NO Contact Closing 7 ... 21 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 or 2 x M6 screws placed diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 4 ... 35 mm² Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² Rigid 1/2x 6 ... 3 5 mm² Rigid 1/2x 6 ... 35 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping LengthControl Circuit 10 mm Main Circuit 16 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal TypeScrew Terminals
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 60 A
Tightening Torque UL/CSAControl Circuit 11 in·lb Main Circuit 35 in·lb
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SBL341201R8600