- AFC52-30-00-85
ABB AFC52-30-00-85 is a 3-pole AC contactor, manufacturer ID 1SBL361001R8500. It has three normally open main contacts and no auxiliary contacts. Rated operational voltage of the main circuit is 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 53 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 60 °C, 45 A at 500 V, and 35 A at 690 V. Rated operational power AC-3 is 22 kW at 380/400 V, 30 kW at 415 V, 440 V, 500 V, and 690 V, and 15 kW at 220/230/240 V. Dimensions are 55 mm width, 119.5 mm depth, 111 mm height, 0.98 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC52-30-00-86
ABB AFC52-30-00-86 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, weighing 0.98 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 105 A at 40 °C. AC-3 ratings at 60 °C include 53 A at 415 V and 35 A at 690 V, with rated operational power of 22 kW at 380/400 V and 30 kW at 415 V. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC52-30-00-88
ABB AFC52-30-00-88 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 55 mm wide, 119.5 mm deep, and 111 mm high, and weighs 0.98 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 100 A at 690 V and 40 °C, 80 A at 60 °C, and 70 A at 70 °C. AC-3 ratings include 53 A at 380/400 V and 60 °C, with 22 kW at 380/400 V. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.
- AFC52-30-11-42
ABB AFC52-30-11-42 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Rated operational current AC-3 is 53 A at 380/400 V, 415 V, 440 V, and 220/230/240 V at 60 °C, 45 A at 500 V, and 35 A at 690 V. Rated operational power AC-3 is 22 kW at 380/400 V and 30 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC52-30-11-51
ABB AFC52-30-11-51 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 53 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 45 A at 500 V, and 35 A at 690 V, all at 60 °C. Rated operational power AC-3 is 22 kW at 380/400 V and 30 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC52-30-11-80
ABB AFC52-30-11-80 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 53 A at 415 V and 440 V, 45 A at 500 V, and 35 A at 690 V, all at 60 °C. Rated operational power AC-3 is 22 kW at 380/400 V and 30 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC52-30-11-81
ABB AFC52-30-11-81 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 53 A at 415 V and 60 °C, and AC-3 rated power is 30 kW at 415 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL361001R8111.
- AFC52-30-11-84
The ABB AFC52-30-11-84 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. AC-3 rated operational current at 415 V and 60 °C is 53 A, with rated operational power of 30 kW at 415 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-4-1.