- AFC78-30-00-88
The ABB AFC78-30-00-88 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Rated operational current AC-1 is 105 A at 40 °C, 90 A at 60 °C, and 80 A at 70 °C, all at 690 V. Rated operational current AC-3 is 80 A at 380/400 V and 220/230/240 V, and 70 A at 440 V, at 60 °C. Rated operational power AC-3 is 37 kW at 380/400 V and 45 kW at 415 V. Dimensions are 55 mm wide, 119.5 mm deep, and 111 mm high, with a net weight of 0.98 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC78-30-11-34
ABB AC contactor AFC78-30-11-34, manufacturer ID 1SBL301001R3411. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. AC-3 ratings include 80 A at 380/400 V and 415 V, and 70 A at 440 V, all at 60 °C. AC-3 power ratings are 37 kW at 380/400 V and 45 kW at 415 V. Dimensions are 67 mm wide, 119.5 mm deep, and 111 mm high; weight is 1.02 kg.
- AFC78-30-11-42
ABB AFC78-30-11-42 is a three-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Rated insulation voltage is 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA.
- AFC78-30-11-51
ABB AC contactor AFC78-30-11-51 (manufacturer ID 1SBL301001R5111) is a three-pole device with three normally open main contacts and one NO plus one NC auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, weighing 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 380/400 V, and 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V.
- AFC78-30-11-80
The ABB AFC78-30-11-80 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 60 °C, with rated operational power AC-3 of 45 kW at 415 V. Maximum breaking capacity is 950 A at 440 V and 600 A at 690 V.
- AFC78-30-11-81
ABB AC contactor AFC78-30-11-81, manufacturer ID 1SBL301001R8111. Three normally open main contacts, one normally open and one normally closed auxiliary contact. Main circuit rated 690 V at 50/60 Hz. Rated operational current AC-1: 105 A at 40 °C, 90 A at 60 °C, and 80 A at 70 °C, all at 690 V. Rated operational current AC-3: 80 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, each at 60 °C. Rated operational power AC-3: 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Dimensions 67 mm wide, 119.5 mm deep, 111 mm high; weight 1.02 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC78-30-11-85
ABB AFC78-30-11-85 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, weighing 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 80 A at 415 V, 60 °C, with rated operational power of 45 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC78-30-11-86
ABB AFC78-30-11-86 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 80 A at 415 V, 440 V, and 380/400 V, and 70 A at 440 V, all at 60 °C. AC-3 power ratings are 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.