- AFC78-30-11-86
ABB AFC78-30-11-86 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 80 A at 415 V, 440 V, and 380/400 V, and 70 A at 440 V, all at 60 °C. AC-3 power ratings are 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC78-30-11-88
ABB AFC78-30-11-88 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 105 A at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 380/400 V, and 220/230/240 V, and 70 A at 440 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC80-22-00-34
The ABB AFC80-22-00-34 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 90 mm wide, 119.5 mm deep, and 116 mm high, weighing 1.45 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 125 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 80 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, and 49 A at 690 V at 60 °C. AC-3 rated power is 45 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC80-22-00-42
The ABB AFC80-22-00-42 is an AC contactor with manufacturer ID 1SBL391501R4200. It has two normally open and two normally closed main contacts, with no auxiliary contacts. Dimensions are 90 mm wide, 119.5 mm deep, and 116 mm high, weighing 1.45 kg. The main circuit is rated 1000 V, 50/60 Hz. Conventional free-air thermal current is 125 A at 40 °C per IEC 60947-4-1. AC-3 ratings include 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC80-22-00-51
ABB AC contactor AFC80-22-00-51, manufacturer ID 1SBL391501R5100. It has two normally open and two normally closed main contacts, with no auxiliary contacts. Dimensions are 90 mm wide, 119.5 mm deep, and 116 mm high; net weight 1.45 kg. The main circuit is rated 1000 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 125 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 440 V, and 380/400 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC80-22-00-80
The ABB AFC80-22-00-80 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 90 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.45 kg. The main circuit is rated 1000 V, with conventional free-air thermal current of 125 A at 40 °C per IEC 60947-4-1. Rated operational current AC-1 is 125 A at 40 °C and 105 A at 60 °C at 690 V. AC-3 ratings include 80 A at 415 V and 440 V, and 65 A at 500 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC80-22-00-81
The ABB AFC80-22-00-81 is a four-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It is rated 1000 V in the main circuit and carries a conventional free-air thermal current of 125 A at 40 °C per IEC 60947-4-1. Rated operational current AC-3 is 80 A at 415 V and 440 V at 60 °C, and rated operational power AC-3 is 45 kW at 415 V, 440 V, 500 V, and 690 V. The coil is rated 24 V at 50 Hz and 60 Hz. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1. Dimensions are 90 mm wide, 119.5 mm deep, and 116 mm high; weight is 1.45 kg.
- AFC80-22-00-84
ABB AFC80-22-00-84 is a four-pole AC contactor with two normally open and two normally closed main contacts and no auxiliary contacts. It measures 90 mm wide, 119.5 mm deep, and 116 mm high, and weighs 1.45 kg. The main circuit is rated 1000 V, with conventional free-air thermal current 125 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 125 A at 690 V and 40 °C, 105 A at 60 °C, and 90 A at 70 °C. AC-3 ratings include 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.