- AFC78-30-11-51
ABB AC contactor AFC78-30-11-51 (manufacturer ID 1SBL301001R5111) is a three-pole device with three normally open main contacts and one NO plus one NC auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, weighing 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 380/400 V, and 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V.
- AFC78-30-11-80
The ABB AFC78-30-11-80 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C, and 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 60 °C, with rated operational power AC-3 of 45 kW at 415 V. Maximum breaking capacity is 950 A at 440 V and 600 A at 690 V.
- AFC78-30-11-81
ABB AC contactor AFC78-30-11-81, manufacturer ID 1SBL301001R8111. Three normally open main contacts, one normally open and one normally closed auxiliary contact. Main circuit rated 690 V at 50/60 Hz. Rated operational current AC-1: 105 A at 40 °C, 90 A at 60 °C, and 80 A at 70 °C, all at 690 V. Rated operational current AC-3: 80 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, each at 60 °C. Rated operational power AC-3: 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Dimensions 67 mm wide, 119.5 mm deep, 111 mm high; weight 1.02 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC78-30-11-85
ABB AFC78-30-11-85 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, weighing 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 rated operational current is 80 A at 415 V, 60 °C, with rated operational power of 45 kW at 415 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC78-30-11-86
ABB AFC78-30-11-86 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-3 ratings include 80 A at 415 V, 440 V, and 380/400 V, and 70 A at 440 V, all at 60 °C. AC-3 power ratings are 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC78-30-11-88
ABB AFC78-30-11-88 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 67 mm wide, 119.5 mm deep, and 111 mm high, and weighs 1.02 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 105 A at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 380/400 V, and 220/230/240 V, and 70 A at 440 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 37 kW at 380/400 V, and 22 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-4-1.
- AFC80-22-00-34
The ABB AFC80-22-00-34 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 90 mm wide, 119.5 mm deep, and 116 mm high, weighing 1.45 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 125 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 80 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, and 49 A at 690 V at 60 °C. AC-3 rated power is 45 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC80-22-00-42
The ABB AFC80-22-00-42 is an AC contactor with manufacturer ID 1SBL391501R4200. It has two normally open and two normally closed main contacts, with no auxiliary contacts. Dimensions are 90 mm wide, 119.5 mm deep, and 116 mm high, weighing 1.45 kg. The main circuit is rated 1000 V, 50/60 Hz. Conventional free-air thermal current is 125 A at 40 °C per IEC 60947-4-1. AC-3 ratings include 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.