- AF26-40-00-12
The ABB AF26-40-00-12 is an AC contactor with four normally open main contacts and no normally closed main or auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.36 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C, 40 A at 60 °C, and 32 A at 70 °C. AC-3 ratings include 22 A at 380/400 V and 10.5 A at 690 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AF26-40-00-13
The ABB AF26-40-00-13 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a control circuit frequency of 50/60 Hz. The conventional free-air thermal current is 55 A at 40 °C, and the rated operational current AC-1 is 45 A at 40 °C, 40 A at 60 °C, and 32 A at 70 °C, all at 690 V. AC-3 ratings include 22 A at 380/400 V and 11 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, with a net weight of 0.36 kg.
- AF26-40-00-13LU
The ABB AF26-40-00-13LU is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. Its control circuit operates at 100-250 V AC/DC and 50/60 Hz. The main circuit is rated 690 V with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V per IEC 60947-4-1 and 600 V per UL/CSA. Rated operational current AC-1 is 45 A at 690 V and 40 °C, and AC-3 is 22 A at 380/400 V and 60 °C. Rated operational power AC-3 is 11 kW at 400 V. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high; net weight is 0.36 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-4-1.
- AF26-40-00-14
The ABB AF26-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 690 V in the main circuit and 6 kV impulse withstand voltage, with screw terminals and IP20 protection on both coil and main terminals. AC-3 rated operational power is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. The rated control circuit voltage is 250 to 500 V at 50 Hz, 250 to 500 V at 60 Hz, and 250 to 500 V DC. Dimensions are 45 mm width, 101 mm depth, and 86 mm height, weighing 0.4 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 or on two M4 screws. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF26-40-00-14LU
ABB AF26-40-00-14LU is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V, with control and main circuit rated frequency 50/60 Hz. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C, 40 A at 60 °C, and 32 A at 70 °C. AC-3 ratings include 22 A at 380/400 V and 60 °C, and 10.5 A at 690 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-4-1.
- AF260-30-00-70
ABB AF260-30-00-70 AC contactor, manufacturer ID 1SFL537001R7000. It has 3 main contacts NO, 0 main contacts NC, and 0 auxiliary contacts NO/NC. Main circuit ratings: 690 V, 50/60 Hz, Ith 400 A per IEC 60947-4-1 at 40 °C open contactors. AC-3 ratings include 260 A at 415 V and 55 °C, 240 A at 440 V and 55 °C, 220 A at 690 V and 55 °C, and 140 kW at 415 V. Coil control voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC. Dimensions are 140 mm width, 180.5 mm depth, 227 mm height, 5.05 kg. Main terminals are bars; main terminals IP00, coil terminals IP20.
- AF260-30-11-69
ABB AF260-30-11-69 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, 240 A at 440 V and 500 V, and 220 A at 690 V. Rated operational power AC-3 includes 140 kW at 415 V and 200 kW at 690 V. Short-circuit protection uses gG type fuses rated 500 A. Dimensions are 140 mm wide, 180.5 mm deep, 227 mm high; net weight 5.05 kg.
- AF260-30-11-70
ABB AF260-30-11-70 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 400 A at 690 V and 40 °C, 350 A at 55 °C, and 290 A at 70 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, and 220 A at 690 V and 55 °C. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high; net weight is 5.1 kg. Short-circuit protection uses gG type fuses rated 500 A.