- AF260-30-11-70
ABB AF260-30-11-70 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 400 A at 690 V and 40 °C, 350 A at 55 °C, and 290 A at 70 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, and 220 A at 690 V and 55 °C. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high; net weight is 5.1 kg. Short-circuit protection uses gG type fuses rated 500 A.
- AF260-30-11-72
The ABB AF260-30-11-72 is a non-reversing, 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The coil operates over a 20-60 V DC control voltage range. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, 240 A at 440 V and 500 V, and 220 A at 690 V. Rated operational power AC-3 is 140 kW at 415 V and 440 V, 180 kW at 500 V, and 200 kW at 690 V. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high, weighing 5.05 kg.
- AF260-30-22-69
The ABB AF260-30-22-69 is a 3-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180.5 mm deep, and 227 mm high, and weighs 5.05 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, 240 A at 440 V and 55 °C, and 220 A at 690 V and 55 °C. Rated operational power AC-3 is 140 kW at 415 V and 200 kW at 690 V. Short-circuit protection uses gG type fuses rated 500 A.
- AF260-30-22-70
ABB AF260-30-22-70 is a 3-pole non-reversing AC contactor with three normally open main contacts and no normally closed main contacts. It provides two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, 240 A at 440 V and 55 °C, and 220 A at 690 V and 55 °C. Rated operational power AC-3 is 140 kW at 415 V and 200 kW at 690 V. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high; net weight is 5.1 kg.
- AF260-30-22-72
ABB AF260-30-22-72 AC contactor, manufacturer ID 1SFL537001R7222. Three normally open main contacts and two normally open plus two normally closed auxiliary contacts. Main circuit rated 690 V at 50/60 Hz. Conventional free-air thermal current per IEC 60947-4-1, open contactors at 40 °C, is 400 A. Rated operational current AC-3 is 260 A at 415 V and 380/400 V, 240 A at 440 V and 500 V, and 220 A at 690 V, all at 55 °C. Rated operational power AC-3 is 140 kW at 415 V, 440 V, and 380/400 V, 180 kW at 500 V, and 200 kW at 690 V. Dimensions: 140 mm wide, 180.5 mm deep, 227 mm high; 5.1 kg.
- AF260B-30-11-69
ABB AF260B-30-11-69 is a non-reversing 3-pole AC contactor, manufacturer ID 1SFL537063R6911. It has 3 main contacts NO, 0 main contacts NC, and 1 auxiliary contact NO plus 1 auxiliary contact NC. Main circuit rated operational voltage is 690 V at 50/60 Hz. Conventional free-air thermal current Ith is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, 240 A at 440 V and 55 °C, and 220 A at 690 V and 55 °C. Rated operational power AC-3 is 140 kW at 415 V and 200 kW at 690 V. Dimensions are 140 mm width, 180.5 mm depth, 227 mm height, 5.5 kg.
- AF260B-30-11-72
ABB AF260B-30-11-72 is a three-phase non-reversing AC contactor with an electronically controlled coil. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Rated operational voltage of the main circuit is 690 V. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, 240 A at 440 V and 55 °C, and 220 A at 690 V and 55 °C. Rated operational power AC-3 is 140 kW at 415 V and 200 kW at 690 V. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high; net weight is 5.5 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF264
ABB AF264 is an industrial catalog item. Key specifications include Product Net Width: 86 mm, Product Net Height: 35 mm, Product Net Depth / Length: 86 mm, and Product Net Weight: 140 g. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.