- AF26-40-00-14
The ABB AF26-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 690 V in the main circuit and 6 kV impulse withstand voltage, with screw terminals and IP20 protection on both coil and main terminals. AC-3 rated operational power is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. The rated control circuit voltage is 250 to 500 V at 50 Hz, 250 to 500 V at 60 Hz, and 250 to 500 V DC. Dimensions are 45 mm width, 101 mm depth, and 86 mm height, weighing 0.4 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 or on two M4 screws. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF26-40-00-14LU
ABB AF26-40-00-14LU is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V, with control and main circuit rated frequency 50/60 Hz. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C, 40 A at 60 °C, and 32 A at 70 °C. AC-3 ratings include 22 A at 380/400 V and 60 °C, and 10.5 A at 690 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-4-1.
- AF260-30-00-70
ABB AF260-30-00-70 AC contactor, manufacturer ID 1SFL537001R7000. It has 3 main contacts NO, 0 main contacts NC, and 0 auxiliary contacts NO/NC. Main circuit ratings: 690 V, 50/60 Hz, Ith 400 A per IEC 60947-4-1 at 40 °C open contactors. AC-3 ratings include 260 A at 415 V and 55 °C, 240 A at 440 V and 55 °C, 220 A at 690 V and 55 °C, and 140 kW at 415 V. Coil control voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC. Dimensions are 140 mm width, 180.5 mm depth, 227 mm height, 5.05 kg. Main terminals are bars; main terminals IP00, coil terminals IP20.
- AF260-30-11-69
ABB AF260-30-11-69 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, 240 A at 440 V and 500 V, and 220 A at 690 V. Rated operational power AC-3 includes 140 kW at 415 V and 200 kW at 690 V. Short-circuit protection uses gG type fuses rated 500 A. Dimensions are 140 mm wide, 180.5 mm deep, 227 mm high; net weight 5.05 kg.
- AF260-30-11-70
ABB AF260-30-11-70 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 400 A at 690 V and 40 °C, 350 A at 55 °C, and 290 A at 70 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, and 220 A at 690 V and 55 °C. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high; net weight is 5.1 kg. Short-circuit protection uses gG type fuses rated 500 A.
- AF260-30-11-72
The ABB AF260-30-11-72 is a non-reversing, 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The coil operates over a 20-60 V DC control voltage range. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, 240 A at 440 V and 500 V, and 220 A at 690 V. Rated operational power AC-3 is 140 kW at 415 V and 440 V, 180 kW at 500 V, and 200 kW at 690 V. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high, weighing 5.05 kg.
- AF260-30-22-69
The ABB AF260-30-22-69 is a 3-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 140 mm wide, 180.5 mm deep, and 227 mm high, and weighs 5.05 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, 240 A at 440 V and 55 °C, and 220 A at 690 V and 55 °C. Rated operational power AC-3 is 140 kW at 415 V and 200 kW at 690 V. Short-circuit protection uses gG type fuses rated 500 A.
- AF260-30-22-70
ABB AF260-30-22-70 is a 3-pole non-reversing AC contactor with three normally open main contacts and no normally closed main contacts. It provides two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 260 A at 415 V and 55 °C, 240 A at 440 V and 55 °C, and 220 A at 690 V and 55 °C. Rated operational power AC-3 is 140 kW at 415 V and 200 kW at 690 V. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high; net weight is 5.1 kg.