- CA5-22MRT
The ABB CA5-22MRT is a front-mounted auxiliary contact block with four poles: two normally open (NO) and two normally closed (NC) auxiliary contacts. It uses ring-tongue screw terminals. Dimensions are 43 mm width, 39 mm depth, and 47 mm height, with a net weight of 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals provide IP10 protection according to IEC 60529, IEC 60947-1, and EN 60529. Suitable for A9 through A40, AL9 through AL40, and TAL9 through TAL40.
- CA5-22N
The ABB CA5-22N is a front-mounted auxiliary contact block with screw terminals, identified by manufacturer ID 1SBN010040R1222. It provides two normally open (NO) and two normally closed (NC) auxiliary contacts. The auxiliary circuit is rated 690 V at 50/60 Hz, with AC-15 rated operational current of 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A / 144 W at 24 V and 0.30 A / 66 W at 220 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Dimensions are 43 mm width, 39 mm depth, 47 mm height, 0.06 kg. Mechanical durability is 10 million operations.
- CA5-22NRT
The ABB CA5-22NRT is a front-mounted auxiliary contact block with four poles: 2 N.O. and 2 N.C. instantaneous contacts. It uses ring-tongue terminals. Dimensions are 43 mm wide, 39 mm deep, and 47 mm high; net weight is 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A / 144 W at 24 V and 0.3 A / 75 W at 250 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Auxiliary terminals provide IP10 per IEC 60529, IEC 60947-1, and EN 60529. Suitable for N22E, N31E, N40E, NL22E, NL31E, NL40E, TNL22E, TNL31E, and TNL40E.
- CA5-22U
ABB auxiliary contact block, model CA5-22U, manufacturer ID 1SBN010040R1322. It provides 2 normally open and 2 normally closed auxiliary contacts. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated short-time withstand current is 140 A for 0.1 s and 100 A for 1 s. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Screw terminals. Dimensions: 43 mm width, 39 mm depth, 47 mm height; 0.06 kg.
- CA5-31E
ABB CA5-31E auxiliary contact block, manufacturer ID 1SBN010040R1031. It provides 3 NO and 1 NC auxiliary contacts with screw terminals. Auxiliary circuit rated operational voltage is 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A / 144 W at 24 V and 0.30 A / 66 W at 220 V. Maximum electrical switching frequency is 1200 cycles per hour; maximum mechanical switching frequency is 3600 cycles per hour. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Dimensions are 43 mm wide, 39 mm deep, 47 mm high; net weight 0.06 kg.
- CA5-31ERT
ABB CA5-31ERT auxiliary contact block with three normally open and one normally closed auxiliary contacts. It measures 43 mm wide, 39 mm deep, and 47 mm high, and weighs 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A at 24 V and 0.3 A at 250 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals provide IP10 protection according to IEC 60529, IEC 60947-1, and EN 60529. Terminals are ring-tongue type. Suitable for listed AF, GAF, A, AL, AE, TAL, and TAE contactors.
- CA5-31M
ABB CA5-31M auxiliary contact block, front-mounted with screw terminals. It provides 3 normally open and 1 normally closed auxiliary contacts. Rated operational voltage of the auxiliary circuit is 690 V at 50/60 Hz. Rated operational current AC-15: 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Mechanical durability is 10 million operations; maximum mechanical switching frequency is 3600 cycles per hour. Auxiliary terminals have IP20 degree of protection according to IEC 60529, IEC 60947-1, and EN 60529. Net dimensions are 43 mm width, 39 mm depth, 47 mm height; net weight 0.06 kg.
- CA5-31MRT
The ABB CA5-31MRT is a front-mounted auxiliary contact block with 3 normally open and 1 normally closed auxiliary contacts. It uses ring-tongue terminals and measures 43 mm wide, 39 mm deep, and 47 mm high, with a net weight of 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with rated operational current AC-15 of 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated short-time withstand current is 140 A for 0.1 s and 100 A for 1 s. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals provide IP10 protection according to IEC 60529, IEC 60947-1, and EN 60529. It is suitable for A9 through A40, AL9 through AL40, and TAL9 through TAL40.