ABB CA5-31N auxiliary contact block, manufacturer ID 1SBN010040R1231. It is a front-mount, 4-pole auxiliary contact block with screw terminals, providing 3 normally open (NO) and 1 normally closed (NC) auxiliary contacts. Dimensions are 43 mm wide, 39 mm deep, and 47 mm high; net weight is 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with rated operational current AC-15 of 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Mechanical durability is 10 million operations. Auxiliary terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529. Suitable for N22E, N31E, N40E, NL22E, NL31E, NL40E, TNL22E, TNL31E, and TNL40E.
- CA5-31NRT
ABB auxiliary contact block, model CA5-31NRT, manufacturer ID 1SBN010042R1231. It provides three normally open (NO) and one normally closed (NC) auxiliary contact. Rated operational voltage of the auxiliary circuit is 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated short-time withstand current is 140 A for 0.1 s and 100 A for 1 s. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals have IP10 protection according to IEC 60529, IEC 60947-1, and EN 60529. Terminal type is ring-tongue. Dimensions are 43 mm width, 39 mm depth, 47 mm height, and 0.06 kg weight. Suitable for N22E, N31E, N40E, NL22E, NL31E, NL40E, TNL22E, TNL31E, and TNL40E.
- CA5-31U
ABB CA5-31U auxiliary contact block, manufacturer ID 1SBN010040R1331. It provides 3 normally open and 1 normally closed auxiliary contacts and uses screw terminals. Dimensions are 43 mm width, 39 mm depth, and 47 mm height; net weight is 0.06 kg. The auxiliary circuit is rated 690 V and 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A/144 W at 24 V and 0.3 A/75 W at 250 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529.
- CA5-40E
The ABB CA5-40E is a 4-pole auxiliary contact block with four normally open (NO) contacts and no normally closed contacts. It measures 43 mm wide, 39 mm deep, and 47 mm high, and weighs 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with AC-15 ratings of 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A at 24 V and 0.3 A at 250 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529, and use screw terminals. Maximum electrical switching frequency is 1200 cycles per hour; maximum mechanical switching frequency is 3600 cycles per hour.
- CA5-40ERT
The ABB CA5-40ERT is an auxiliary contact block with four normally open (NO) contacts and no normally closed contacts. It is rated for an auxiliary circuit voltage of 690 V at 50/60 Hz, with AC-15 ratings of 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A at 24 V and 0.30 A at 220 V. Rated short-time withstand current is 140 A for 0.1 s and 100 A for 1 s. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Auxiliary terminals are IP10 per IEC 60529, IEC 60947-1, and EN 60529. Terminal type is ring-tongue. Dimensions are 43 mm width, 39 mm depth, and 47 mm height; net weight is 0.06 kg.
- CA5-40N
ABB CA5-40N auxiliary contact block, manufacturer ID 1SBN010040R1240. It provides four normally open (4 NO) auxiliary contacts and no normally closed contacts, with screw terminals and IP20 protection on the auxiliary terminals according to IEC 60529, IEC 60947-1, and EN 60529. Rated operational voltage of the auxiliary circuit is 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Mechanical durability is 10 million operations, with maximum mechanical switching frequency of 3600 cycles per hour and maximum electrical switching frequency of 1200 cycles per hour. Dimensions are 43 mm width, 39 mm depth, 47 mm height, and 0.06 kg net weight.
- CA5-40N-W
ABB auxiliary contact block, model CA5-40N-W, manufacturer ID 1SBN010040W1240. It provides four normally open (NO) auxiliary contacts and no normally closed contacts, with screw terminals. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated short-time withstand current is 140 A for 0.1 s and 100 A for 1 s. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals have IP20 protection according to IEC 60529, IEC 60947-1, and EN 60529. Dimensions are 43 mm width, 39 mm depth, 47 mm height, and 0.02 kg net weight. Suitable for N22E, N31E, N40E, NL22E, NL31E, NL40E, TNL22E, TNL31E, and TNL40E.
- CA5-40NRT
ABB CA5-40NRT is a front-mounted auxiliary contact block with four normally open (4 NO) and zero normally closed (0 NC) instantaneous contacts. It uses ring-tongue screw terminals and is suitable for N22E, N31E, N40E, NL22E, NL31E, NL40E, TNL22E, TNL31E, and TNL40E. Dimensions are 43 mm width, 39 mm depth, and 47 mm height, with a net weight of 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Auxiliary terminals provide IP10 protection per IEC 60529, IEC 60947-1, and EN 60529.