- CA5-22U
ABB auxiliary contact block, model CA5-22U, manufacturer ID 1SBN010040R1322. It provides 2 normally open and 2 normally closed auxiliary contacts. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated short-time withstand current is 140 A for 0.1 s and 100 A for 1 s. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Screw terminals. Dimensions: 43 mm width, 39 mm depth, 47 mm height; 0.06 kg.
- CA5-31E
ABB CA5-31E auxiliary contact block, manufacturer ID 1SBN010040R1031. It provides 3 NO and 1 NC auxiliary contacts with screw terminals. Auxiliary circuit rated operational voltage is 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A / 144 W at 24 V and 0.30 A / 66 W at 220 V. Maximum electrical switching frequency is 1200 cycles per hour; maximum mechanical switching frequency is 3600 cycles per hour. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Dimensions are 43 mm wide, 39 mm deep, 47 mm high; net weight 0.06 kg.
- CA5-31ERT
ABB CA5-31ERT auxiliary contact block with three normally open and one normally closed auxiliary contacts. It measures 43 mm wide, 39 mm deep, and 47 mm high, and weighs 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A at 24 V and 0.3 A at 250 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals provide IP10 protection according to IEC 60529, IEC 60947-1, and EN 60529. Terminals are ring-tongue type. Suitable for listed AF, GAF, A, AL, AE, TAL, and TAE contactors.
- CA5-31M
ABB CA5-31M auxiliary contact block, front-mounted with screw terminals. It provides 3 normally open and 1 normally closed auxiliary contacts. Rated operational voltage of the auxiliary circuit is 690 V at 50/60 Hz. Rated operational current AC-15: 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Mechanical durability is 10 million operations; maximum mechanical switching frequency is 3600 cycles per hour. Auxiliary terminals have IP20 degree of protection according to IEC 60529, IEC 60947-1, and EN 60529. Net dimensions are 43 mm width, 39 mm depth, 47 mm height; net weight 0.06 kg.
- CA5-31MRT
The ABB CA5-31MRT is a front-mounted auxiliary contact block with 3 normally open and 1 normally closed auxiliary contacts. It uses ring-tongue terminals and measures 43 mm wide, 39 mm deep, and 47 mm high, with a net weight of 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with rated operational current AC-15 of 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated short-time withstand current is 140 A for 0.1 s and 100 A for 1 s. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals provide IP10 protection according to IEC 60529, IEC 60947-1, and EN 60529. It is suitable for A9 through A40, AL9 through AL40, and TAL9 through TAL40.
- CA5-31N
ABB CA5-31N auxiliary contact block, manufacturer ID 1SBN010040R1231. It is a front-mount, 4-pole auxiliary contact block with screw terminals, providing 3 normally open (NO) and 1 normally closed (NC) auxiliary contacts. Dimensions are 43 mm wide, 39 mm deep, and 47 mm high; net weight is 0.06 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with rated operational current AC-15 of 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Mechanical durability is 10 million operations. Auxiliary terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529. Suitable for N22E, N31E, N40E, NL22E, NL31E, NL40E, TNL22E, TNL31E, and TNL40E.
- CA5-31NRT
ABB auxiliary contact block, model CA5-31NRT, manufacturer ID 1SBN010042R1231. It provides three normally open (NO) and one normally closed (NC) auxiliary contact. Rated operational voltage of the auxiliary circuit is 690 V at 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. Rated short-time withstand current is 140 A for 0.1 s and 100 A for 1 s. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Auxiliary terminals have IP10 protection according to IEC 60529, IEC 60947-1, and EN 60529. Terminal type is ring-tongue. Dimensions are 43 mm width, 39 mm depth, 47 mm height, and 0.06 kg weight. Suitable for N22E, N31E, N40E, NL22E, NL31E, NL40E, TNL22E, TNL31E, and TNL40E.
- CA5-31U
ABB CA5-31U auxiliary contact block, manufacturer ID 1SBN010040R1331. It provides 3 normally open and 1 normally closed auxiliary contacts and uses screw terminals. Dimensions are 43 mm width, 39 mm depth, and 47 mm height; net weight is 0.06 kg. The auxiliary circuit is rated 690 V and 50/60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 380/400 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A/144 W at 24 V and 0.3 A/75 W at 250 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529.