- CM-ENE MAX
ABB CM-ENE MAX intermediate relay, manufacturer ID 1SVR550855R9400, is a filling monitoring relay with overflow protection. It uses two electrodes and a measuring range of 0 to 100 kΩ. The rated control supply voltage is 24 V AC at 50/60 Hz. Output is one normally open contact; rated operational currents are 4 A AC-12 at 230 V, 3 A AC-15 at 230 V, 4 A DC-12 at 24 V, and 2 A DC-13 at 24 V. Terminals are screw type. Dimensions are 22.5 mm wide, 78 mm high, and 78.5 mm deep; net weight is 0.106 kg. Housing protection is IP50 and terminals IP20. Rated impulse withstand voltage is 4 kV and rated insulation voltage is 250 V across the stated circuit pairs. Output circuit NO short-circuit protection uses 10 A type F fuses.
- CM-ENE MIN
The ABB CM-ENE MIN is an intermediate relay for draining monitoring with dry running protection. It accepts two electrodes and has a measuring range of 0 to 100 kOhm. The rated control supply voltage is 24 V AC at 50/60 Hz. Output is one normally open contact. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Rated impulse withstand voltage is 4 kV and rated insulation voltage is 250 V for the measuring, output, and supply circuits. The housing measures 22.5 mm wide, 78 mm high, and 78.5 mm deep, weighs 0.106 kg, uses screw terminals, and provides IP50 housing and IP20 terminal protection. Output circuit NO fuses are 10 A type F.
- CM-ENS.11P
The ABB CM-ENS.11P is a liquid level monitoring relay for filling or draining control, with three electrodes and a measuring range of 5 to 100 kΩ. It operates from a rated control supply voltage of 24 to 240 V AC/DC at 50/60 Hz and provides one changeover (SPDT) output contact. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13, with a minimum switching capacity of 12 V 10 mA. The relay measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighs 0.117 kg, and uses screwless terminals. Housing protection is IP50 and terminal protection is IP20; overvoltage category is III.
- CM-ENS.11S
ABB CM-ENS.11S intermediate relay for filling or draining monitoring, order code 1SVR730850R0100. It uses three electrodes and measures resistance over a 5 to 100 kΩ range. Rated control supply voltage is 24 to 240 V AC/DC, with a supply circuit rated frequency of 50/60 Hz. Output is one changeover (SPDT) contact; rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 12 V, 10 mA. Screw terminals are provided. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight is 0.124 kg. Housing protection is IP50, terminals IP20, overvoltage category III.
- CM-ENS.13P
The ABB CM-ENS.13P is an intermediate relay for filling or draining monitoring, using three electrodes. Its measuring range is 5 ... 100 kΩ. The rated control supply voltage is 110 ... 130 V AC and 220 ... 240 V AC at 50/60 Hz. Output is one c/o (SPDT) contact with screwless terminals. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 12 V 10 mA. Rated impulse withstand voltage is 4 kV across the stated circuit pairs, and rated insulation voltage is 300 V. Degree of protection is IP50 for the housing and IP20 for terminals. Overvoltage category III. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight 0.145 kg.
- CM-ENS.13S
The ABB CM-ENS.13S is a level monitoring relay for filling or draining functions, using three electrodes to measure liquid resistance over a 5 to 100 kΩ range. It operates on a rated control supply voltage of 110 to 130 V AC or 220 to 240 V AC at 50/60 Hz. The output is one changeover (SPDT) contact, with rated operational currents of 4 A AC-12 at 230 V, 3 A AC-15 at 230 V, 4 A DC-12 at 24 V, and 2 A DC-13 at 24 V. Screw terminals accept rigid conductors from 0.5 to 4 mm². The housing measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighs 0.153 kg, and mounts on 35 mm DIN rail per IEC 60715. Operating ambient temperature is -25 to +60 °C.
- CM-ENS.21P
ABB CM-ENS.21P intermediate relay for filling or draining monitoring, manufacturer ID 1SVR740850R0200. It uses three electrodes and a measuring range of 0.1 to 1000 kΩ. Rated control supply voltage is 24 to 240 V AC/DC; supply circuit rated frequency is 50/60 Hz. Output is one changeover (SPDT) contact. Rated operational current is 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 12 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight 0.117 kg. Housing protection is IP50, terminals IP20. Terminal type is screwless.
- CM-ENS.21S
The ABB CM-ENS.21S is a level monitoring relay for filling or draining monitoring, using 3 electrodes. Its rated control supply voltage is 24 to 240 V AC/DC at 50/60 Hz. The output is one changeover (SPDT) contact, with rated operational currents of 4 A AC-12 at 230 V, 3 A AC-15 at 230 V, 4 A DC-12 at 24 V, and 2 A DC-13 at 24 V. Terminals are screw type. The housing measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, and weighs 0.125 kg. Ambient operating temperature is -25 to +60 degrees C. Standards include IEC/EN 60255-27, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, and CAN/CSA C22.2 No.14.