- CM-ENS.21S
The ABB CM-ENS.21S is a level monitoring relay for filling or draining monitoring, using 3 electrodes. Its rated control supply voltage is 24 to 240 V AC/DC at 50/60 Hz. The output is one changeover (SPDT) contact, with rated operational currents of 4 A AC-12 at 230 V, 3 A AC-15 at 230 V, 4 A DC-12 at 24 V, and 2 A DC-13 at 24 V. Terminals are screw type. The housing measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, and weighs 0.125 kg. Ambient operating temperature is -25 to +60 degrees C. Standards include IEC/EN 60255-27, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, and CAN/CSA C22.2 No.14.
- CM-ENS.23P
ABB CM-ENS.23P intermediate relay for filling or draining monitoring, with three electrodes and a measuring range of 0.1 to 1000 kΩ. Rated control supply voltage is 110 to 130 V AC or 220 to 240 V AC at 50/60 Hz. Output is one changeover (SPDT) contact; rated operational currents are 4 A AC-12 at 230 V, 3 A AC-15 at 230 V, 4 A DC-12 at 24 V, and 2 A DC-13 at 24 V. Minimum switching capacity is 12 V, 10 mA. Screwless terminals accept 2 x 0.5 to 1.5 mm². Dimensions are 22.5 x 85.6 x 103.7 mm; weight 0.147 kg. Housing IP50, terminals IP20. Ambient operating temperature -25 to +60 °C.
- CM-ENS.23S
The ABB CM-ENS.23S is an intermediate relay for filling or draining monitoring, using three electrodes. It accepts a rated control supply voltage of 110 to 130 V AC or 220 to 240 V AC at 50/60 Hz. Output is one changeover (SPDT) contact with screw terminals. Measuring range is 1 to 1000 kilohm. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, with a net weight of 0.154 kg. Housing protection is IP50 and terminals IP20. Operation is rated for ambient air temperatures of -25 to +60 degrees Celsius. The device mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715.
- CM-ENS.31P
The ABB CM-ENS.31P intermediate relay (manufacturer ID 1SVR740850R0300) monitors filling or draining of conductive fluids using three electrodes. It measures resistance from 0.1 to 1000 kΩ and provides a selectable tripping delay of 0 s or 0.1 to 30 s (ON or OFF). The rated control supply voltage is 24 to 240 V AC/DC at 50/60 Hz. Output is two changeover (SPDT) contacts, rated 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13, with a minimum switching capacity of 12 V, 10 mA. The unit measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighs 0.134 kg, uses screwless terminals, and has IP50 housing and IP20 terminal protection.
- CM-ENS.31S
ABB CM-ENS.31S intermediate relay for filling or draining monitoring, manufacturer ID 1SVR730850R0300. It uses three electrodes and a measuring range of 0.1 to 1000 kΩ. Tripping delay is selectable at 0 s or 0.1 to 30 s (ON or OFF). Rated control supply voltage is 24 to 240 V AC/DC at 50/60 Hz. Output is two changeover (SPDT) contacts with screw terminals. Rated operational currents are 4 A AC-12 at 230 V, 3 A AC-15 at 230 V, 4 A DC-12 at 24 V, and 2 A DC-13 at 24 V. Minimum switching capacity is 12 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight 0.143 kg. Housing protection is IP50, terminals IP20.
- CM-ESS.1P
The ABB CM-ESS.1P intermediate relay performs over- or undervoltage monitoring. Its measuring range covers 3 to 30 V, 6 to 60 V, 30 to 300 V, and 60 to 600 V. Rated control supply voltage is 220 to 240 V AC. The output is one changeover (SPDT) contact, with rated operational currents of 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 24 V, 10 mA. Connections use screwless terminals with 8 mm stripping length. The housing measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighs 0.155 kg, and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- CM-ESS.1S
ABB CM-ESS.1S intermediate relay, manufacturer ID 1SVR730830R0300, provides over- or undervoltage monitoring. Measuring ranges are 3 to 30 V, 6 to 60 V, 30 to 300 V, and 60 to 600 V. Rated control supply voltage is 24 to 240 V AC/DC. Output is one changeover (SPDT) contact with screw terminals. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 24 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight is 0.135 kg. Housing protection is IP50, terminals IP20, overvoltage category III, pollution degree 3.
- CM-ESS.2P
ABB CM-ESS.2P intermediate relay, order code 1SVR740831R0400, for over- or undervoltage monitoring. Measuring ranges are 3 to 30 V, 6 to 60 V, 30 to 300 V, and 60 to 600 V. Tripping delay is 0 s or 0.1 to 30 s (ON). Rated control supply voltage is 110 to 130 V AC. Output is two changeover (SPDT) contacts. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13; minimum switching capacity is 24 V, 10 mA. Rated impulse withstand voltage is 6 kV measuring/supply to output, 4 kV output to output. Rated insulation voltage is 600 V measuring/supply to output, 250 V supply to output. Dimensions are 22.5 mm wide, 85.6 mm high, 103.7 mm deep; weight 0.17 kg. Housing IP50, terminals IP20, overvoltage category III, pollution degree 3.