- CM-ENS.13P
The ABB CM-ENS.13P is an intermediate relay for filling or draining monitoring, using three electrodes. Its measuring range is 5 ... 100 kΩ. The rated control supply voltage is 110 ... 130 V AC and 220 ... 240 V AC at 50/60 Hz. Output is one c/o (SPDT) contact with screwless terminals. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 12 V 10 mA. Rated impulse withstand voltage is 4 kV across the stated circuit pairs, and rated insulation voltage is 300 V. Degree of protection is IP50 for the housing and IP20 for terminals. Overvoltage category III. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight 0.145 kg.
- CM-ENS.13S
The ABB CM-ENS.13S is a level monitoring relay for filling or draining functions, using three electrodes to measure liquid resistance over a 5 to 100 kΩ range. It operates on a rated control supply voltage of 110 to 130 V AC or 220 to 240 V AC at 50/60 Hz. The output is one changeover (SPDT) contact, with rated operational currents of 4 A AC-12 at 230 V, 3 A AC-15 at 230 V, 4 A DC-12 at 24 V, and 2 A DC-13 at 24 V. Screw terminals accept rigid conductors from 0.5 to 4 mm². The housing measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighs 0.153 kg, and mounts on 35 mm DIN rail per IEC 60715. Operating ambient temperature is -25 to +60 °C.
- CM-ENS.21P
ABB CM-ENS.21P intermediate relay for filling or draining monitoring, manufacturer ID 1SVR740850R0200. It uses three electrodes and a measuring range of 0.1 to 1000 kΩ. Rated control supply voltage is 24 to 240 V AC/DC; supply circuit rated frequency is 50/60 Hz. Output is one changeover (SPDT) contact. Rated operational current is 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 12 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight 0.117 kg. Housing protection is IP50, terminals IP20. Terminal type is screwless.
- CM-ENS.21S
The ABB CM-ENS.21S is a level monitoring relay for filling or draining monitoring, using 3 electrodes. Its rated control supply voltage is 24 to 240 V AC/DC at 50/60 Hz. The output is one changeover (SPDT) contact, with rated operational currents of 4 A AC-12 at 230 V, 3 A AC-15 at 230 V, 4 A DC-12 at 24 V, and 2 A DC-13 at 24 V. Terminals are screw type. The housing measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, and weighs 0.125 kg. Ambient operating temperature is -25 to +60 degrees C. Standards include IEC/EN 60255-27, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508, and CAN/CSA C22.2 No.14.
- CM-ENS.23P
ABB CM-ENS.23P intermediate relay for filling or draining monitoring, with three electrodes and a measuring range of 0.1 to 1000 kΩ. Rated control supply voltage is 110 to 130 V AC or 220 to 240 V AC at 50/60 Hz. Output is one changeover (SPDT) contact; rated operational currents are 4 A AC-12 at 230 V, 3 A AC-15 at 230 V, 4 A DC-12 at 24 V, and 2 A DC-13 at 24 V. Minimum switching capacity is 12 V, 10 mA. Screwless terminals accept 2 x 0.5 to 1.5 mm². Dimensions are 22.5 x 85.6 x 103.7 mm; weight 0.147 kg. Housing IP50, terminals IP20. Ambient operating temperature -25 to +60 °C.
- CM-ENS.23S
The ABB CM-ENS.23S is an intermediate relay for filling or draining monitoring, using three electrodes. It accepts a rated control supply voltage of 110 to 130 V AC or 220 to 240 V AC at 50/60 Hz. Output is one changeover (SPDT) contact with screw terminals. Measuring range is 1 to 1000 kilohm. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, with a net weight of 0.154 kg. Housing protection is IP50 and terminals IP20. Operation is rated for ambient air temperatures of -25 to +60 degrees Celsius. The device mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715.
- CM-ENS.31P
The ABB CM-ENS.31P intermediate relay (manufacturer ID 1SVR740850R0300) monitors filling or draining of conductive fluids using three electrodes. It measures resistance from 0.1 to 1000 kΩ and provides a selectable tripping delay of 0 s or 0.1 to 30 s (ON or OFF). The rated control supply voltage is 24 to 240 V AC/DC at 50/60 Hz. Output is two changeover (SPDT) contacts, rated 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13, with a minimum switching capacity of 12 V, 10 mA. The unit measures 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighs 0.134 kg, uses screwless terminals, and has IP50 housing and IP20 terminal protection.
- CM-ENS.31S
ABB CM-ENS.31S intermediate relay for filling or draining monitoring, manufacturer ID 1SVR730850R0300. It uses three electrodes and a measuring range of 0.1 to 1000 kΩ. Tripping delay is selectable at 0 s or 0.1 to 30 s (ON or OFF). Rated control supply voltage is 24 to 240 V AC/DC at 50/60 Hz. Output is two changeover (SPDT) contacts with screw terminals. Rated operational currents are 4 A AC-12 at 230 V, 3 A AC-15 at 230 V, 4 A DC-12 at 24 V, and 2 A DC-13 at 24 V. Minimum switching capacity is 12 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight 0.143 kg. Housing protection is IP50, terminals IP20.