- NFBAC17016
ABB spare part, manufacturer ID NFBAC17016, described in the supplied data as SCR PAN HD-B ST. The product type and frame size are listed as Spare_Parts. No ABB type designation is supplied. Product net weight is 0 kg and gross weight is 0 kg, with a gross volume of 0 in³. The item is not made to order and is not quote only. Order multiple is 1 EA. Stocked at Wickliffe, Ohio, United States. No technical ratings, standards, certifications, or compatibility information are provided in the source data.
- NFC22E-34
ABB NFC22E-34 intermediate relay, manufacturer ID 1SBH131001R3422. It has no main contacts, with 2 auxiliary contacts NO and 2 auxiliary contacts NC. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.3 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC22E-42
ABB NFC22E-42 intermediate relay, manufacturer ID 1SBH131001R4222. It has 2 auxiliary contacts NO and 2 auxiliary contacts NC, with no main contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.3 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated control circuit voltage is 230 to 240 V at 50 Hz and 277 V at 60 Hz. Coil consumption is 2.3 W. Standards include IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC22E-51
The ABB NFC22E-51 is an intermediate relay with 2 NO and 2 NC auxiliary contacts and no main contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.3 kg. The rated control circuit voltage is 400 to 415 V at 50 Hz and 480 V at 60 Hz, with a coil consumption of 2.3 W. The relay is rated for an auxiliary circuit operational voltage of 690 V and a frequency of 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Maximum mechanical switching frequency is 6000 cycles per hour. It conforms to IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14.
- NFC22E-80
The ABB NFC22E-80 is an intermediate relay with two normally open and two normally closed auxiliary contacts, and no main contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.3 kg. Rated operational voltage for the auxiliary circuit is 690 V, with a rated insulation voltage of 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. The relay is covered by IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14. Coil consumption is 2.3 W.
- NFC22E-81
The ABB NFC22E-81 is an intermediate relay with 2 normally open and 2 normally closed auxiliary contacts and no main contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.309 kg. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz; conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Coil consumption is 2.3 W at 24 V control voltage, 50/60 Hz. Screw terminals accept rigid or flexible conductors from 0.75 to 2.5 mm², with 10 mm stripping length. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on 2 x M4 screws placed diagonally. Standards include IEC/EN 60947-1 and IEC/EN 60947-5-1.
- NFC22E-84
ABB NFC22E-84 intermediate relay (manufacturer ID 1SBH131001R8422) with 2 NO and 2 NC auxiliary contacts and no main NC contacts. Rated operational voltage of the auxiliary circuit is 690 V; rated frequency is 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A per IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W with a rated control circuit voltage of 110 V at 50 Hz and 110 to 120 V at 60 Hz. Dimensions are 45 mm width, 77 mm depth, and 86 mm height, weighing 0.306 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC22E-85
ABB NFC22E-85 intermediate relay, manufacturer ID 1SBH131001R8522. It has 2 auxiliary contacts NO and 2 auxiliary contacts NC, with no main contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.3 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.