- NFC22E-81
The ABB NFC22E-81 is an intermediate relay with 2 normally open and 2 normally closed auxiliary contacts and no main contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.309 kg. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz; conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Coil consumption is 2.3 W at 24 V control voltage, 50/60 Hz. Screw terminals accept rigid or flexible conductors from 0.75 to 2.5 mm², with 10 mm stripping length. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on 2 x M4 screws placed diagonally. Standards include IEC/EN 60947-1 and IEC/EN 60947-5-1.
- NFC22E-84
ABB NFC22E-84 intermediate relay (manufacturer ID 1SBH131001R8422) with 2 NO and 2 NC auxiliary contacts and no main NC contacts. Rated operational voltage of the auxiliary circuit is 690 V; rated frequency is 50/60 Hz for auxiliary, control, and main circuits. Conventional free-air thermal current is 16 A per IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Coil consumption is 2.3 W with a rated control circuit voltage of 110 V at 50 Hz and 110 to 120 V at 60 Hz. Dimensions are 45 mm width, 77 mm depth, and 86 mm height, weighing 0.306 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC22E-85
ABB NFC22E-85 intermediate relay, manufacturer ID 1SBH131001R8522. It has 2 auxiliary contacts NO and 2 auxiliary contacts NC, with no main contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.3 kg. The auxiliary circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC22E-86
ABB NFC22E-86 intermediate relay, manufacturer ID 1SBH131001R8622. It has 2 NO and 2 NC auxiliary contacts and no main contacts. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A per IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 400–415 V at 50 Hz and 415–440 V at 60 Hz. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14. Net dimensions 45 x 77 x 86 mm; weight 0.3 kg.
- NFC22E-88
ABB NFC22E-88 intermediate relay, manufacturer ID 1SBH131001R8822. It has two auxiliary NO contacts and two auxiliary NC contacts, with no main NC contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight is 0.301 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC22EK-34
ABB NFC22EK-34 intermediate relay, manufacturer ID 1SBH131005R3422. It has two auxiliary contacts NO and two auxiliary contacts NC, with no main contacts. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight 0.306 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC22EK-42
ABB NFC22EK-42 intermediate relay, manufacturer ID 1SBH131005R4222. It has two normally open and two normally closed auxiliary contacts, with no main contacts. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight 0.306 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 230 to 240 V at 50 Hz and 277 V at 60 Hz, with coil consumption 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.
- NFC22EK-51
ABB NFC22EK-51 intermediate relay, manufacturer ID 1SBH131005R5122. It has two normally open and two normally closed auxiliary contacts, with no main contacts. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; net weight 0.306 kg. Rated operational voltage is 690 V for auxiliary and main circuits, at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated control circuit voltage is 400 to 415 V at 50 Hz and 480 V at 60 Hz; coil consumption is 2.3 W. Standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14.