Product Model
NFC22E-84
Material Number
1SBH131001R8422
Manufacturer
ABB
Product ID
83329

Get a Free Quote

Request pricing and availability for NFC22E-84.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.306 kg
Rated Operational Voltage
Auxiliary Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Rated Operational Current AC-15 (Ie)
(500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 A for 1 s 100 A
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
See all specifications

Product Highlights

  1. Contact Configuration: 2 normally open (NO) and 2 normally closed (NC) auxiliary contacts, with no main contacts
  2. Switching Capacity: Conventional free-air thermal current 16 A at 40 °C, rated operational current AC-15 from 6 A at 24/127 V to 2 A at 690 V, and DC-13 ratings from 6 A / 144 W at 24 V to 0.1 A / 60 W at 600 V
  3. Coil and Switching Speed: Rated control circuit voltage 110 V at 50 Hz and 110 to 120 V at 60 Hz, coil consumption 2.3 W, maximum mechanical switching frequency 6000 cycles per hour, and operate times of 4 to 26 ms depending on contact transition
  4. Electrical Ratings: Rated operational voltage 690 V for the auxiliary circuit, rated insulation voltage 690 V per IEC 60947-5-1 and 600 V per UL/CSA, rated impulse withstand voltage 6 kV, and rated short-time withstand current 140 A for 0.1 s and 100 A for 1 s
  5. Mounting and Connections: 45 x 77 x 86 mm, 0.306 kg, DIN rail mounting on TH35-15 or TH35-7.5 rails or diagonal M4 screw mounting, screw terminals with 10 mm stripping length, and IP20 protection on auxiliary and coil terminals
  6. Operating Conditions: Ambient operating temperature -40 to 70 °C, storage temperature -60 to 80 °C, maximum operating altitude 3000 m without derating, and vibration resistance 4 g closed and 2 g open at 5 to 300 Hz
  7. Standards and Compliance: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, and CSA C22.2 No. 60947-5-1-14
NFC22E-84

Product Information

Technical Specifications

Specifications for NFC22E-84

ParameterValue
Product Net Width45 mm
Product Net Depth / Length77 mm
Product Net Height86 mm
Product Net Weight0.306 kg
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
StandardsIEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 5060 Hz Control Circuit 5060 Hz Main Circuit 5060 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A (690 V) 2 A (24127 V) 6 A (220240 V) 4 A (400440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A for 1 s 100 A
Maximum Electrical Switching Frequency(AC-1) 0 cycles per hour (AC-15) 1200 cycles per hour (AC-2 / AC-4) 0 cycles per hour (AC-3) 0 cycles per hour (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)(24 V) 6 A144 W (48 V) 2.8 A134 W (72 V) 1 A72 W (110 V) 0.55 A60 W (125 V) 0.55 A69 W (220 V) 0.27 A60 W (250 V) 0.27 A68 W (400 V) 0.15 A60 W (500 V) 0.13 A65 W (600 V) 0.1 A60 W
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Mechanical Switching Frequency6000 cycles per hour
ParameterValue
Rated Control Circuit Voltage (Uc)50 Hz 110 V 60 Hz 110 ... 120 V
Coil Consumption2.3 W
Operate TimeBetween Coil De-energization and NC Contact Closing 9 ... 20 ms Between Coil De-energization and NO Contact Opening 4 ... 18 ms Between Coil Energization and NC Contact Opening 7 ... 21 ms Between Coil Energization and NO Contact Closing 10 ... 26 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 screws placed diagonally
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm Control Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal TypeScrew Terminals
Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb Control Circuit 11 in·lb
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +60 °C Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g
Resistance to Vibrations4g Closed Position & 2g Open position 5 ... 300 Hz
Object Classification CodeK
ETIM 7EC000196 - Contactor relay
ETIM 8EC000196 - Contactor relay
ETIM 9EC000196 - Contactor relay
eClassV11.0 : 27371001
UNSPSC39121500
IDEA Granular Category Code (IGCC)4755 >> Contactors
Manufacturer ID1SBH131001R8422