- AFC38-40-00-86
ABB AFC38-40-00-86 is an AC contactor with four normally open main contacts and no auxiliary contacts. The main circuit is rated 690 V, with a rated frequency of 50/60 Hz for both main and auxiliary circuits. Conventional free-air thermal current is 55 A per IEC 60947-4-1 for open contactors at 40 °C. AC-1 rated operational current is 55 A at 690 V and 40 °C, 45 A at 60 °C, and 37 A at 70 °C. AC-3 ratings include 22 A at 380/400 V and 11 kW at 400 V, both at 60 °C. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high; weight is 0.393 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC38-40-00-88
ABB AC contactor AFC38-40-00-88, manufacturer ID 1SBL291201R8800. Four normally open main contacts, no normally closed main contacts, and no auxiliary contacts. Main circuit rated operational voltage 690 V; control and main circuit rated frequency 50/60 Hz. Conventional free-air thermal current per IEC 60947-4-1, open contactors at 40 °C, is 55 A. Rated operational current AC-1 at 690 V is 55 A at 40 °C, 45 A at 60 °C, and 37 A at 70 °C. Rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Rated insulation voltage 690 V per IEC 60947-4-1 and 600 V per UL/CSA; rated impulse withstand voltage 6 kV. Dimensions 45 mm wide, 101 mm deep, 86 mm high; net weight 0.394 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC40-22-00-34
ABB AFC40-22-00-34 AC contactor, manufacturer ID 1SBL341501R3400. It has two normally open and two normally closed main contacts, with no auxiliary contacts. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high; net weight is 1.18 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 40 A at 415 V and 440 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC40-22-00-42
ABB AFC40-22-00-42 is a 4-pole AC contactor, manufacturer ID 1SBL341501R4200, with two normally open and two normally closed main contacts and no auxiliary contacts. Main circuit rated operational voltage is 690 V at 50/60 Hz. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. AC-3 ratings include 40 A at 415 V and 60 °C, and 25 A at 690 V and 60 °C. Rated operational power AC-3 is 22 kW at 415 V and 11 kW at 220/230/240 V. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high, weighing 1.18 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC40-22-00-51
ABB AFC40-22-00-51 AC contactor, manufacturer ID 1SBL341501R5100, for switching three-phase motors and power circuits. It has 2 normally open and 2 normally closed main contacts, with no auxiliary contacts. Main circuit rated operational voltage is 690 V at 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V, 18.5 kW at 380/400 V, and 11 kW at 220/230/240 V. Dimensions are 70 mm wide, 119.5 mm deep, 113.5 mm high; weight 1.18 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC40-22-00-80
The ABB AFC40-22-00-80 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. The coil is rated 220 to 230 V at 50 Hz and 230 to 240 V at 60 Hz. Main circuit rated operational voltage is 690 V; rated operational current AC-3 is 40 A at 415 V and 40 A at 440 V, both at 60 °C. Screw terminals are used. Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high, with a net weight of 1.18 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AFC40-22-00-81
ABB AFC40-22-00-81 AC contactor, manufacturer ID 1SBL341501R8100. Four-pole device with 2 main contacts NO and 2 main contacts NC; no auxiliary contacts. Rated operational voltage of main circuit is 690 V; rated insulation voltage is 690 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 690 V and 60 °C, and 50 A at 690 V and 70 °C. AC-3 rating is 40 A at 415 V and 60 °C, with rated operational power 22 kW at 415 V. Coil is rated 24 V at 50 Hz and 24 V at 60 Hz. Screw terminals; dimensions 70 mm wide, 119.5 mm deep, 113.5 mm high; net weight 1.18 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, CSA C22.2 No. 60947-4-1.
- AFC40-22-00-84
The ABB AFC40-22-00-84 is a 4-pole AC contactor with 2 NO and 2 NC main contacts and no auxiliary contacts. It is rated 690 V in the main circuit and carries 70 A at 40 °C, 60 A at 60 °C, and 50 A at 70 °C under AC-1. AC-3 ratings include 40 A at 415 V and 25 A at 690 V, with 22 kW at 415 V. The coil operates at 110 V, 50 Hz or 110 to 120 V, 60 Hz. Screw terminals accept main-circuit conductors from 4 to 35 mm². Dimensions are 70 mm wide, 119.5 mm deep, and 113.5 mm high; weight is 1.18 kg. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.