- AF80-40-00-14LU
The ABB AF80-40-00-14LU is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.44 kg. The main circuit is rated 1000 V, with a rated impulse withstand voltage of 8 kV and a rated insulation voltage of 1000 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Conventional free-air thermal current is 125 A at 40 °C per IEC 60947-4-1. AC-3 rated operational current is 80 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, and 65 A at 500 V, all at 60 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80B-22-00-12
ABB AF80B-22-00-12 AC contactor, manufacturer ID 1SBL397561R1200. It has two normally open and two normally closed main contacts, with no auxiliary contacts. Main circuit rated operational voltage is 1000 V; control and main circuit rated frequency is 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational power includes 37 kW at 380/400 V and 45 kW at 415/440/500/690 V. Dimensions are 90 mm wide, 116 mm deep, and 125.5 mm high; net weight is 1.49 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80B-22-00-14
ABB AF80B-22-00-14 AC contactor, manufacturer ID 1SBL397561R1400. It has two normally open and two normally closed main contacts, with no auxiliary contacts. Main circuit rated operational voltage is 1000 V; control and main circuit rated frequency is 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 440 V, and 380/400 V at 60 °C. Rated operational power AC-3 is 37 kW at 380/400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 116 mm deep, and 125.5 mm high; net weight 1.44 kg.
- AF80B-30-00-11
ABB AF80B-30-00-11 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 116 mm deep, and 125.5 mm high, weighing 1.22 kg. The main circuit is rated 1000 V, with a control circuit frequency of 50/60 Hz. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 37 kW at 400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, and UL 60947-4-1.
- AF80B-30-00-12
ABB AF80B-30-00-12 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.22 kg. The main circuit is rated 1000 V, with a control and main circuit frequency of 50/60 Hz. Conventional free-air thermal current is 130 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80B-30-00-13
ABB AF80B-30-00-13 AC contactor, manufacturer ID 1SBL397061R1300. Three main contacts NO, no auxiliary contacts. Rated operational voltage 1000 V main circuit; rated frequency 50/60 Hz for control and main circuits. Rated control circuit voltage 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Rated operational power AC-3: 37 kW at 380/400 V and 400 V, 45 kW at 415, 440, 500 and 690 V, 35 kW at 1000 V, 22 kW at 220/230/240 V. Dimensions 70 mm wide, 116 mm deep, 125.5 mm high; 1.17 kg. Screw terminals; DIN rail TH35-15 per IEC 60715. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF80B-30-00-14
The ABB AF80B-30-00-14 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.17 kg. The main circuit is rated 1000 V, with a control circuit frequency of 50/60 Hz. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 37 kW at 400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80B-30-11-11
ABB AF80B-30-11-11 AC contactor, manufacturer ID 1SBL397061R1111. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Dimensions are 82 mm wide, 116 mm deep, and 125.5 mm high, with a net weight of 1.26 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 440 V, 500 V, and 690 V, and 37 kW at 380/400 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.