- AF80B-30-00-12
ABB AF80B-30-00-12 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.22 kg. The main circuit is rated 1000 V, with a control and main circuit frequency of 50/60 Hz. Conventional free-air thermal current is 130 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80B-30-00-13
ABB AF80B-30-00-13 AC contactor, manufacturer ID 1SBL397061R1300. Three main contacts NO, no auxiliary contacts. Rated operational voltage 1000 V main circuit; rated frequency 50/60 Hz for control and main circuits. Rated control circuit voltage 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Rated operational power AC-3: 37 kW at 380/400 V and 400 V, 45 kW at 415, 440, 500 and 690 V, 35 kW at 1000 V, 22 kW at 220/230/240 V. Dimensions 70 mm wide, 116 mm deep, 125.5 mm high; 1.17 kg. Screw terminals; DIN rail TH35-15 per IEC 60715. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF80B-30-00-14
The ABB AF80B-30-00-14 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.17 kg. The main circuit is rated 1000 V, with a control circuit frequency of 50/60 Hz. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 37 kW at 400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80B-30-11-11
ABB AF80B-30-11-11 AC contactor, manufacturer ID 1SBL397061R1111. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Dimensions are 82 mm wide, 116 mm deep, and 125.5 mm high, with a net weight of 1.26 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 440 V, 500 V, and 690 V, and 37 kW at 380/400 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80B-30-11-12
ABB AF80B-30-11-12 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 82 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.26 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 440 V, 500 V, and 690 V, and 35 kW at 1000 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80B-30-11-13
The ABB AF80B-30-11-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It uses screw terminals and mounts on TH35-15 (35 x 15 mm) DIN rail per IEC 60715, or on 2 x M4 or 2 x M6 screws placed diagonally. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational power AC-3 is 37 kW at 380/400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 82 mm wide, 116 mm deep, and 125.5 mm high, with a net weight of 1.21 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, and UL 60947-4-1.
- AF80B-30-11-14
The ABB AF80B-30-11-14 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It uses screw terminals and measures 82 mm wide, 116 mm deep, and 125.5 mm high, weighing 1.21 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational power AC-3 is 37 kW at 380/400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. Conventional free-air thermal current is 130 A according to IEC 60947-4-1 at 40 °C. It mounts on TH35-15 DIN rail per IEC 60715 or with two M4 or M6 screws. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, and UL 60947-4-1.
- AF80B-40-00-11
ABB AF80B-40-00-11 AC contactor, manufacturer ID 1SBL397261R1100. Four main contacts NO, no NC main or auxiliary contacts. Rated operational voltage 1000 V main circuit; rated frequency 50/60 Hz for control and main circuits. Rated control circuit voltage 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Conventional free-air thermal current 125 A per IEC 60947-4-1 at 40 °C, open contactors. Rated operational current AC-3: 80 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C; 65 A at 500 V; 49 A at 690 V; 25 A at 1000 V. Dimensions 90 mm wide, 116 mm deep, 125.5 mm high; 1.49 kg. Screw terminals; DIN-rail TH35-15 mounting per IEC 60715 or diagonal M4/M6 screws.