- AF80B-30-11-12
ABB AF80B-30-11-12 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 82 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.26 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational current AC-3 is 80 A at 415 V and 440 V, 65 A at 500 V, 49 A at 690 V, and 25 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 440 V, 500 V, and 690 V, and 35 kW at 1000 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80B-30-11-13
The ABB AF80B-30-11-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It uses screw terminals and mounts on TH35-15 (35 x 15 mm) DIN rail per IEC 60715, or on 2 x M4 or 2 x M6 screws placed diagonally. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational power AC-3 is 37 kW at 380/400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 82 mm wide, 116 mm deep, and 125.5 mm high, with a net weight of 1.21 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, and UL 60947-4-1.
- AF80B-30-11-14
The ABB AF80B-30-11-14 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It uses screw terminals and measures 82 mm wide, 116 mm deep, and 125.5 mm high, weighing 1.21 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational power AC-3 is 37 kW at 380/400 V and 45 kW at 415 V, 440 V, 500 V, and 690 V. Conventional free-air thermal current is 130 A according to IEC 60947-4-1 at 40 °C. It mounts on TH35-15 DIN rail per IEC 60715 or with two M4 or M6 screws. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, and UL 60947-4-1.
- AF80B-40-00-11
ABB AF80B-40-00-11 AC contactor, manufacturer ID 1SBL397261R1100. Four main contacts NO, no NC main or auxiliary contacts. Rated operational voltage 1000 V main circuit; rated frequency 50/60 Hz for control and main circuits. Rated control circuit voltage 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Conventional free-air thermal current 125 A per IEC 60947-4-1 at 40 °C, open contactors. Rated operational current AC-3: 80 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C; 65 A at 500 V; 49 A at 690 V; 25 A at 1000 V. Dimensions 90 mm wide, 116 mm deep, 125.5 mm high; 1.49 kg. Screw terminals; DIN-rail TH35-15 mounting per IEC 60715 or diagonal M4/M6 screws.
- AF80B-40-00-12
ABB AF80B-40-00-12 is an AC contactor with four normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 116 mm deep, and 125.5 mm high, weighing 1.49 kg. The main circuit is rated 1000 V, with control and main circuit frequencies of 50/60 Hz. Conventional free-air thermal current is 125 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 80 A at 415 V, 440 V, and 380/400 V at 60 °C. Rated operational power AC-3 is 37 kW at 380/400 V and 45 kW at 415 V, 440 V, and 500 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, and UL 60947-4-1.
- AF80B-40-00-13
The ABB AF80B-40-00-13 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.44 kg. The main circuit is rated 1000 V, with a control and main circuit frequency of 50/60 Hz. Conventional free-air thermal current is 125 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 80 A at 415 V and 440 V, and rated operational power is 37 kW at 380/400 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF80B-40-00-14
The ABB AF80B-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It has a rated operational voltage of 1000 V for the main circuit and a rated control circuit voltage of 250 to 500 V at 50 Hz, 60 Hz, and DC operation. Rated operational current AC-3 is 80 A at 415 V and 440 V, both at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 116 mm deep, and 125.5 mm high, with a net weight of 1.44 kg. It uses screw terminals and mounts on TH35-15 DIN rail per IEC 60715 or with 2 x M4 or 2 x M6 screws placed diagonally. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF95-30-00-70
The ABB AF95-30-00-70 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 415 V and 55 °C, 93 A at 440 V and 55 °C, 80 A at 500 V and 55 °C, 65 A at 690 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V, 440 V, 500 V, and 690 V, and 40 kW at 1000 V. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.9 kg.