- AF80B-40-00-14
The ABB AF80B-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It has a rated operational voltage of 1000 V for the main circuit and a rated control circuit voltage of 250 to 500 V at 50 Hz, 60 Hz, and DC operation. Rated operational current AC-3 is 80 A at 415 V and 440 V, both at 60 °C. Rated operational power AC-3 is 45 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 116 mm deep, and 125.5 mm high, with a net weight of 1.44 kg. It uses screw terminals and mounts on TH35-15 DIN rail per IEC 60715 or with 2 x M4 or 2 x M6 screws placed diagonally. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF95-30-00-70
The ABB AF95-30-00-70 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 415 V and 55 °C, 93 A at 440 V and 55 °C, 80 A at 500 V and 55 °C, 65 A at 690 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V, 440 V, 500 V, and 690 V, and 40 kW at 1000 V. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.9 kg.
- AF95-30-00-72
ABB AC contactor AF95-30-00-72, manufacturer ID 1SFL437001R7200. It has three normally open main contacts and no normally open or normally closed auxiliary contacts. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high; net weight 1.9 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 415 V and 55 °C, 93 A at 440 V and 55 °C, 80 A at 500 V and 55 °C, 65 A at 690 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 55 °C.
- AF95-30-11-69
The ABB AF95-30-11-69 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 96 A at 415 V and 55 °C, with rated operational power of 55 kW at 415 V. AC-3 making capacity is 10 x Ie and breaking capacity is 8 x Ie. Short-circuit protection uses gG type fuses rated 160 A. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.9 kg.
- AF95-30-11-70
The ABB AF95-30-11-70 is a 3-phase non-reversing AC contactor, manufacturer ID 1SFL437001R7011. It has three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 96 A at 415 V and 55 °C, and 30 A at 1000 V and 55 °C. AC-3 rated operational power is 55 kW at 415 V and 40 kW at 1000 V. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.9 kg. Short-circuit protection uses gG type fuses rated 160 A.
- AF95-30-11-72
The ABB AF95-30-11-72 is a three-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated for operation up to 1000 V. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 415 V and 55 °C, 80 A at 500 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 40 kW at 1000 V. Short-circuit protection uses gG type fuses rated 160 A.
- AF95-30-22-69
ABB AF95-30-22-69 is a 3-pole AC contactor with 3 main contacts NO and 0 main contacts NC, plus 2 auxiliary contacts NO and 2 auxiliary contacts NC. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current Ith is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 415 V and 55 °C, 93 A at 440 V and 55 °C, 80 A at 500 V and 55 °C, 65 A at 690 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V, 440 V, 500 V, and 690 V, and 40 kW at 1000 V. Dimensions are 90 mm width, 156.5 mm depth, 148 mm height, 1.9 kg.
- AF95-30-22-70
ABB AF95-30-22-70 AC contactor, manufacturer ID 1SFL437001R7022. It has three normally open main contacts and two normally open plus two normally closed auxiliary contacts. Main circuit rated operational voltage is 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A per IEC 60947-4-1, open contactors, 40 °C. Rated operational current AC-3 is 96 A at 415 V and 55 °C, 93 A at 440 V and 55 °C, 80 A at 500 V and 55 °C, 65 A at 690 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 55 °C, and 40 kW at 1000 V and 55 °C. Dimensions are 90 mm wide, 156.5 mm deep, 148 mm high; net weight 1.9 kg.