- AF95-30-22-72
The ABB AF95-30-22-72 is a 3-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 156.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 415 V and 55 °C, 93 A at 440 V and 55 °C, 80 A at 500 V and 55 °C, 65 A at 690 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V, 440 V, 500 V, and 690 V, and 40 kW at 1000 V.
- AF95B-30-00RT-70
The ABB AF95B-30-00RT-70 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 1000 V in the main circuit at 50/60 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 96 A at 415 V and 55 °C, and 30 A at 1000 V and 55 °C. AC-3 rated operational power is 55 kW at 415 V and 40 kW at 1000 V. Short-circuit protection uses gG type fuses rated 160 A. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.9 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, and EN 50155.
- AF95B-30-11 100-250V 50/60Hz / DC
ABB AF95B-30-11 100-250V 50/60Hz / DC is a three-pole AC contactor with three main contacts NO, no main contacts NC, and one auxiliary contact NO plus one NC. Main circuit rated operational voltage is 1000 V at 50/60 Hz. Conventional free-air thermal current Ith is 145 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 380/400 V and 415 V, 93 A at 440 V, 80 A at 500 V, 65 A at 690 V, and 30 A at 1000 V, all at 55 °C. Dimensions are 102 mm width, 123.5 mm depth, 148 mm height, 2.1 kg net weight. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, EN 50155, TR CU 001/2011, and IEC 61373.
- AF95B-30-11-69
The ABB AF95B-30-11-69 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, weighing 1.9 kg. The main circuit is rated 1000 V at 50/60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 degrees C. AC-3 rated operational current is 96 A at 415 V and 55 degrees C. Coil voltage range is 48 to 130 V for 50 Hz, 60 Hz, and DC operation. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF95B-30-11-72
The ABB AF95B-30-11-72 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. Its main circuit is rated 1000 V, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. The DC control coil operates from 20 to 60 V. Rated operational current AC-3 is 96 A at 415 V and 55 °C, and rated operational power AC-3 is 55 kW at 415 V. Dimensions are 102 mm width, 123.5 mm depth, and 148 mm height, with a net weight of 1.9 kg. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF95B-30-11RT-69
The ABB AF95B-30-11RT-69 is a 3-phase AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. The rated control circuit voltage is 48 to 130 V at 50 Hz, 48 to 130 V at 60 Hz, and 48 to 130 V DC. The main circuit is rated 1000 V at 50/60 Hz, with AC-3 ratings of 96 A at 415 V and 55 kW at 415 V, both at 55 °C. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, weighing 1.9 kg. Coil terminals are IP20 and main terminals IP10. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, EN 50155, TR CU 001/2011, and IEC 61373.
- AF95B-30-11RT-70
The ABB AF95B-30-11RT-70 is a three-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Its rated operational voltage for the main circuit is 1000 V at 50/60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. The rated impulse withstand voltage for the main circuit is 8 kV. The control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, and DC operation. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.9 kg. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, EN 50155, TR CU 001/2011, and IEC 61373.
- AF95B-30-11RT-72
The ABB AF95B-30-11RT-72 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Its DC-operated control circuit accepts 20 to 60 V, with coil operating limits of 0.85 x Uc minimum to 1.1 x Uc maximum at temperatures up to 70 °C. The main circuit is rated 1000 V, with conventional free-air thermal current of 145 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 96 A at 415 V and 55 °C, and 65 A at 690 V and 55 °C. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, weighing 1.9 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.