- AF95-30-11-69
The ABB AF95-30-11-69 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 96 A at 415 V and 55 °C, with rated operational power of 55 kW at 415 V. AC-3 making capacity is 10 x Ie and breaking capacity is 8 x Ie. Short-circuit protection uses gG type fuses rated 160 A. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.9 kg.
- AF95-30-11-70
The ABB AF95-30-11-70 is a 3-phase non-reversing AC contactor, manufacturer ID 1SFL437001R7011. It has three normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A per IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 96 A at 415 V and 55 °C, and 30 A at 1000 V and 55 °C. AC-3 rated operational power is 55 kW at 415 V and 40 kW at 1000 V. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.9 kg. Short-circuit protection uses gG type fuses rated 160 A.
- AF95-30-11-72
The ABB AF95-30-11-72 is a three-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated for operation up to 1000 V. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 415 V and 55 °C, 80 A at 500 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 40 kW at 1000 V. Short-circuit protection uses gG type fuses rated 160 A.
- AF95-30-22-69
ABB AF95-30-22-69 is a 3-pole AC contactor with 3 main contacts NO and 0 main contacts NC, plus 2 auxiliary contacts NO and 2 auxiliary contacts NC. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current Ith is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 415 V and 55 °C, 93 A at 440 V and 55 °C, 80 A at 500 V and 55 °C, 65 A at 690 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V, 440 V, 500 V, and 690 V, and 40 kW at 1000 V. Dimensions are 90 mm width, 156.5 mm depth, 148 mm height, 1.9 kg.
- AF95-30-22-70
ABB AF95-30-22-70 AC contactor, manufacturer ID 1SFL437001R7022. It has three normally open main contacts and two normally open plus two normally closed auxiliary contacts. Main circuit rated operational voltage is 1000 V at 50/60 Hz. Conventional free-air thermal current is 145 A per IEC 60947-4-1, open contactors, 40 °C. Rated operational current AC-3 is 96 A at 415 V and 55 °C, 93 A at 440 V and 55 °C, 80 A at 500 V and 55 °C, 65 A at 690 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 55 °C, and 40 kW at 1000 V and 55 °C. Dimensions are 90 mm wide, 156.5 mm deep, 148 mm high; net weight 1.9 kg.
- AF95-30-22-72
The ABB AF95-30-22-72 is a 3-phase AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 156.5 mm deep, and 148 mm high, and weighs 1.9 kg. The main circuit is rated 1000 V. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 415 V and 55 °C, 93 A at 440 V and 55 °C, 80 A at 500 V and 55 °C, 65 A at 690 V and 55 °C, and 30 A at 1000 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V, 440 V, 500 V, and 690 V, and 40 kW at 1000 V.
- AF95B-30-00RT-70
The ABB AF95B-30-00RT-70 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It is rated 1000 V in the main circuit at 50/60 Hz. Conventional free-air thermal current is 145 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 ratings include 96 A at 415 V and 55 °C, and 30 A at 1000 V and 55 °C. AC-3 rated operational power is 55 kW at 415 V and 40 kW at 1000 V. Short-circuit protection uses gG type fuses rated 160 A. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.9 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, and EN 50155.
- AF95B-30-11 100-250V 50/60Hz / DC
ABB AF95B-30-11 100-250V 50/60Hz / DC is a three-pole AC contactor with three main contacts NO, no main contacts NC, and one auxiliary contact NO plus one NC. Main circuit rated operational voltage is 1000 V at 50/60 Hz. Conventional free-air thermal current Ith is 145 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 96 A at 380/400 V and 415 V, 93 A at 440 V, 80 A at 500 V, 65 A at 690 V, and 30 A at 1000 V, all at 55 °C. Dimensions are 102 mm width, 123.5 mm depth, 148 mm height, 2.1 kg net weight. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, EN 50155, TR CU 001/2011, and IEC 61373.