- AF116-30-22B-14
The ABB AF116-30-22B-14 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AF116-30-22B-31
The ABB AF116-30-22B-31 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. Dimensions are 110 mm wide, 138.5 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AF116-30-22B-32
The ABB AF116-30-22B-32 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz, with a conventional free-air thermal current of 160 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 116 A at 415 V and 60 °C, and AC-3 rated operational power is 55 kW at 400 V. The control circuit accepts 48 to 130 V at 50 Hz, 60 Hz, or DC. Dimensions are 110 mm wide, 138.5 mm deep, and 150 mm high; net weight is 1.3 kg. Main terminals are bars; coil terminals are IP20 and main terminals IP00 per IEC 60529.
- AF116-30-22B-33
The ABB AF116-30-22B-33 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V.
- AF116-30-22B-34
The ABB AF116-30-22B-34 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 110 A at 500 V, and 65 A at 690 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V.
- AF116-30-22B-42
The ABB AF116-30-22B-42 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz, with AC-3 rated operational current of 116 A at 415 V and 60 °C, and rated operational power of 55 kW at 400 V. Conventional free-air thermal current is 160 A per IEC 60947-4-1 at 40 °C. Rated control circuit voltage is 110 to 120 V at 50 Hz and 60 Hz. Mechanical durability is 5 million operating cycles. Dimensions are 110 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg. Main terminals accept rigid copper cable from 10 to 95 mm².
- AF116-30-22B-43
The ABB AF116-30-22B-43 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 110 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 110 A at 500 V, and 65 A at 690 V, all at 60 °C. Rated operational power AC-3 is 55 kW at 400 V and 30 kW at 220/230/240 V.
- AF116-40-00-12
ABB AF116-40-00-12 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 2.05 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. Rated operational current AC-3 is 116 A at 55 °C for 415 V, 440 V, 380/400 V, and 220/230/240 V. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 200 A.