- AF116-40-00-12
ABB AF116-40-00-12 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 2.05 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. Rated operational current AC-3 is 116 A at 55 °C for 415 V, 440 V, 380/400 V, and 220/230/240 V. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 200 A.
- AF116-40-00-13
The ABB AF116-40-00-13 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 2.05 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. Rated operational current AC-3 is 116 A at 55 °C for 415 V, 440 V, 380/400 V, and 220/230/240 V. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 200 A.
- AF116-40-00-14
ABB AF116-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 690 V in the main circuit at 50 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 40 °C, 145 A at 60 °C, and 130 A at 70 °C at 690 V. Rated operational current AC-3 is 116 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V. Rated operational power AC-3 is 30 kW at 220/230/240 V, 55 kW at 380/400 V and 415 V, and 75 kW at 440 V. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; weight is 2.05 kg.
- AF116-40-00B-11
ABB AF116-40-00B-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, weighing 1.95 kg. The main circuit is rated 690 V at 50 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. AC-3 ratings are 116 A at 415 V, 440 V, and 380/400 V, all at 55 °C. AC-3 power ratings include 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 200 A.
- AF116-40-00B-12
The ABB AF116-40-00B-12 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a main circuit frequency of 60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 160 A at 40 °C for open contactors. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 1.95 kg.
- AF116-40-00B-14
The ABB AF116-40-00B-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 1.95 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 40 °C, 145 A at 60 °C, and 130 A at 70 °C at 690 V. Rated operational current AC-3 is 116 A at 55 °C for 415 V, 440 V, 380/400 V, and 220/230/240 V. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 200 A.
- AF116-40-11-11
The ABB AF116-40-11-11 is a four-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V at 50 Hz, with a rated operational current AC-1 of 160 A at 40 °C and AC-3 of 116 A at 55 °C. Rated operational power AC-3 is 55 kW at 380/400 V and 415 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Coil control voltage is 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Terminals use a double clamp. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high, weighing 2.05 kg.
- AF116-40-11-12
ABB AF116-40-11-12 AC contactor with four main contacts, all normally open, plus one normally open and one normally closed auxiliary contact. Main circuit rated operational voltage is 690 V at 50 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Coil voltage range is 48 to 130 V at 50 Hz, 60 Hz, and DC. Terminals use double clamp. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight 2.05 kg.