- AF116-40-11-13
The ABB AF116-40-11-13 is a four-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. AC-3 ratings include 116 A at 415 V and 55 °C, with rated operational power of 55 kW at 415 V. The control circuit voltage is 100 to 250 V for 50 Hz, 60 Hz, and DC operation. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 2.05 kg. Mechanical durability is 5 million operations.
- AF116-40-11-14
The ABB AF116-40-11-14 is a 4-pole AC contactor with four normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 2.05 kg. The main circuit is rated 690 V at 50 Hz, with a conventional free-air thermal current of 160 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 116 A at 55 °C for 380/400 V, 415 V, 440 V, and 220/230/240 V. AC-3 rated operational power is 55 kW at 380/400 V and 415 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Coil voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC.
- AF116-40-11B-11
The ABB AF116-40-11B-11 is a 4-pole AC contactor with four main contacts NO and no main contacts NC, plus one auxiliary contact NO and one auxiliary contact NC. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. The coil accepts 24 to 60 V at 50 Hz and 60 Hz, and 20 to 60 V DC. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 1.95 kg.
- AF116-40-11B-12
The ABB AF116-40-11B-12 is a 4-pole AC contactor with four normally open main contacts and one NO plus one NC auxiliary contact. The main circuit is rated 690 V at 60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 at 40 °C. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 1.95 kg. Main terminals are bars.
- AF116-40-11B-13
The ABB AF116-40-11B-13 is a 4-pole AC contactor with four normally open main contacts and one NO plus one NC auxiliary contact. The coil accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Rated operational voltage for the main circuit is 690 V, and rated frequency is 50 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 116 A at 415 V and 55 °C, corresponding to 55 kW. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high, with a net weight of 1.95 kg. Main terminals are bars; coil terminals are IP20 and main terminals IP00.
- AF116-40-11B-14
The ABB AF116-40-11B-14 is a 4-pole AC contactor with four normally open main contacts and one NO plus one NC auxiliary contact. It is rated 690 V in the main circuit at 60 Hz, with a conventional free-air thermal current of 160 A at 40 °C per IEC 60947-4-1. AC-3 ratings include 116 A at 415 V and 55 kW at 415 V. The coil accepts 250 to 500 V at 50 Hz, 60 Hz, or DC. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high, weighing 1.95 kg. Main terminals are bars; main terminal protection is IP00 and coil terminals IP20 per IEC 60529.
- AF116-40-22-11
The ABB AF116-40-22-11 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It has two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 40 °C, 145 A at 60 °C, and 130 A at 70 °C at 690 V. Rated operational current AC-3 is 116 A at 55 °C for 415 V, 440 V, 380/400 V, and 220/230/240 V. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V, 55 kW at 380/400 V, and 30 kW at 220/230/240 V. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; weight is 2.05 kg.
- AF116-40-22-12
The ABB AF116-40-22-12 is a 4-pole AC contactor with four main contacts NO and no main contacts NC, plus two auxiliary contacts NO and two auxiliary contacts NC. Main circuit rated operational voltage is 690 V at 50 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. The coil accepts 48 to 130 V at 50 Hz, 60 Hz, and DC. Terminals are double clamp. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight 2.05 kg.