- AF116-40-11B-14
The ABB AF116-40-11B-14 is a 4-pole AC contactor with four normally open main contacts and one NO plus one NC auxiliary contact. It is rated 690 V in the main circuit at 60 Hz, with a conventional free-air thermal current of 160 A at 40 °C per IEC 60947-4-1. AC-3 ratings include 116 A at 415 V and 55 kW at 415 V. The coil accepts 250 to 500 V at 50 Hz, 60 Hz, or DC. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high, weighing 1.95 kg. Main terminals are bars; main terminal protection is IP00 and coil terminals IP20 per IEC 60529.
- AF116-40-22-11
The ABB AF116-40-22-11 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It has two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 40 °C, 145 A at 60 °C, and 130 A at 70 °C at 690 V. Rated operational current AC-3 is 116 A at 55 °C for 415 V, 440 V, 380/400 V, and 220/230/240 V. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V, 55 kW at 380/400 V, and 30 kW at 220/230/240 V. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; weight is 2.05 kg.
- AF116-40-22-12
The ABB AF116-40-22-12 is a 4-pole AC contactor with four main contacts NO and no main contacts NC, plus two auxiliary contacts NO and two auxiliary contacts NC. Main circuit rated operational voltage is 690 V at 50 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. The coil accepts 48 to 130 V at 50 Hz, 60 Hz, and DC. Terminals are double clamp. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight 2.05 kg.
- AF116-40-22-14
The ABB AF116-40-22-14 is a 4-pole AC contactor with four normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 2.05 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, each at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 200 A.
- AF116-40-22B-11
The ABB AF116-40-22B-11 is a 4-pole AC contactor with four normally open main contacts and two NO plus two NC auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a main circuit frequency of 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 1.95 kg.
- AF116-40-22B-12
The ABB AF116-40-22B-12 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts, plus two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. The control circuit voltage range is 48 to 130 V for 50 Hz, 60 Hz, and DC operation. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 1.95 kg.
- AF116-40-22B-13
The ABB AF116-40-22B-13 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It carries two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, each at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. The coil accepts 100 to 250 V at 50 Hz, 60 Hz, and DC. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 1.95 kg.
- AF116-40-22B-14
The ABB AF116-40-22B-14 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It has two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V and 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; weight is 1.95 kg.