- AF116-40-22-14
The ABB AF116-40-22-14 is a 4-pole AC contactor with four normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 2.05 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, each at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 200 A.
- AF116-40-22B-11
The ABB AF116-40-22B-11 is a 4-pole AC contactor with four normally open main contacts and two NO plus two NC auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a main circuit frequency of 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 1.95 kg.
- AF116-40-22B-12
The ABB AF116-40-22B-12 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts, plus two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. The control circuit voltage range is 48 to 130 V for 50 Hz, 60 Hz, and DC operation. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 1.95 kg.
- AF116-40-22B-13
The ABB AF116-40-22B-13 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It carries two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, each at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. The coil accepts 100 to 250 V at 50 Hz, 60 Hz, and DC. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 1.95 kg.
- AF116-40-22B-14
The ABB AF116-40-22B-14 is a 4-pole AC contactor with four normally open main contacts and no normally closed main contacts. It has two normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V and 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; weight is 1.95 kg.
- AF116B-30-22-11
ABB AF116B-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. Main circuit rated operational voltage is 690 V. Rated operational current AC-3 is 116 A at 380/400 V and 55 °C, 110 A at 500 V and 55 °C, and 65 A at 690 V and 55 °C. Rated operational power AC-3 is 55 kW at 380/400 V, 75 kW at 440 V, 75 kW at 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V. Dimensions are 90 mm width, 126 mm depth, and 150 mm height; net weight 1.55 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF116B-30-22-12
The ABB AF116B-30-22-12 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. Main circuit rated operational voltage is 690 V. Rated operational current AC-3 is 116 A at 380/400 V and 55 °C, and rated operational power AC-3 is 55 kW at 380/400 V. Control circuit voltage is 48 to 130 V AC at 50/60 Hz and 48 to 130 V DC. Mechanical durability is 5 million operating cycles, with maximum mechanical switching frequency of 300 cycles per hour. Main circuit terminals are bars. Net dimensions are 90 mm width, 126 mm depth, and 150 mm height; net weight is 1.55 kg. Applicable standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF116B-30-22-13
The ABB AF116B-30-22-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated 690 V in the main circuit, with AC-1 ratings of 160 A at 40 °C, 145 A at 60 °C, and 130 A at 70 °C. AC-3 ratings include 116 A at 415 V and 55 °C, and 65 A at 690 V and 55 °C. Control circuit voltage is 100 to 250 V DC, or 100 to 250 V at 50/60 Hz. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Mechanical durability is 5 million operations. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.