- AF116-30-22B-34
The ABB AF116-30-22B-34 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 110 A at 500 V, and 65 A at 690 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V.
- AF116-30-22B-42
The ABB AF116-30-22B-42 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz, with AC-3 rated operational current of 116 A at 415 V and 60 °C, and rated operational power of 55 kW at 400 V. Conventional free-air thermal current is 160 A per IEC 60947-4-1 at 40 °C. Rated control circuit voltage is 110 to 120 V at 50 Hz and 60 Hz. Mechanical durability is 5 million operating cycles. Dimensions are 110 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg. Main terminals accept rigid copper cable from 10 to 95 mm².
- AF116-30-22B-43
The ABB AF116-30-22B-43 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 110 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 110 A at 500 V, and 65 A at 690 V, all at 60 °C. Rated operational power AC-3 is 55 kW at 400 V and 30 kW at 220/230/240 V.
- AF116-40-00-12
ABB AF116-40-00-12 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 2.05 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. Rated operational current AC-3 is 116 A at 55 °C for 415 V, 440 V, 380/400 V, and 220/230/240 V. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 200 A.
- AF116-40-00-13
The ABB AF116-40-00-13 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, and weighs 2.05 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. Rated operational current AC-3 is 116 A at 55 °C for 415 V, 440 V, 380/400 V, and 220/230/240 V. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 200 A.
- AF116-40-00-14
ABB AF116-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 690 V in the main circuit at 50 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 40 °C, 145 A at 60 °C, and 130 A at 70 °C at 690 V. Rated operational current AC-3 is 116 A at 55 °C for 220/230/240 V, 380/400 V, 415 V, and 440 V. Rated operational power AC-3 is 30 kW at 220/230/240 V, 55 kW at 380/400 V and 415 V, and 75 kW at 440 V. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; weight is 2.05 kg.
- AF116-40-00B-11
ABB AF116-40-00B-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 120 mm wide, 128 mm deep, and 150 mm high, weighing 1.95 kg. The main circuit is rated 690 V at 50 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 160 A at 690 V and 40 °C, 145 A at 60 °C, and 130 A at 70 °C. AC-3 ratings are 116 A at 415 V, 440 V, and 380/400 V, all at 55 °C. AC-3 power ratings include 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Short-circuit protection uses gG type fuses rated 200 A.
- AF116-40-00B-12
The ABB AF116-40-00B-12 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a main circuit frequency of 60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 160 A at 40 °C for open contactors. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V, and 30 kW at 220/230/240 V. Dimensions are 120 mm wide, 128 mm deep, and 150 mm high; net weight is 1.95 kg.