- AF16-30-10-14LU
The ABB AF16-30-10-14LU is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The contactor is rated for a main and auxiliary circuit operational voltage of 690 V at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16-30-10K-11
ABB AF16-30-10K-11 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.285 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16-30-10K-12
The ABB AF16-30-10K-12 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It is rated for a main and auxiliary circuit operational voltage of 690 V and a rated frequency of 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 35 A at 40 °C for open contactors. Rated operational current AC-1 is 30 A at 690 V at both 40 °C and 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V and 10.5 A at 690 V, both at 60 °C. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; weight is 0.285 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16-30-10K-13
ABB AF16-30-10K-13 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It is identified by manufacturer ID 1SBL177005R1310. Per IEC/EN 60947-4-1, conventional free-air thermal current Ith is 35 A at 40 °C for open contactors; rated operational current AC-3 is 18 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Main and auxiliary circuits are rated 690 V, 50/60 Hz. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high; weight 0.285 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16-30-10K-13M
The ABB AF16-30-10K-13M is a 3-pole AC contactor with one built-in auxiliary NO contact and push-in spring terminals. It has three main contacts NO and no main contacts NC. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 18 A at 380/400 V and 60 °C, and rated operational power AC-3 is 7.5 kW at 380/400 V. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.285 kg. Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-16, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16-30-10K-14
The ABB AF16-30-10K-14 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.325 kg. Rated operational voltage is 690 V for both the main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16-30-22-11
The ABB AF16-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16-30-22-12
The ABB AF16-30-22-12 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 18 A at 380/400 V, both at 60 °C, with rated operational power AC-3 of 7.5 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL177001R1222.