- AF16-30-10K-13M
The ABB AF16-30-10K-13M is a 3-pole AC contactor with one built-in auxiliary NO contact and push-in spring terminals. It has three main contacts NO and no main contacts NC. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Rated operational current AC-3 is 18 A at 380/400 V and 60 °C, and rated operational power AC-3 is 7.5 kW at 380/400 V. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C. Dimensions are 45 mm wide, 77 mm deep, and 92.3 mm high, weighing 0.285 kg. Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-16, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16-30-10K-14
The ABB AF16-30-10K-14 is a 3-pole AC contactor with three normally open main contacts and one normally open auxiliary contact. It measures 45 mm wide, 77 mm deep, and 92.3 mm high, and weighs 0.325 kg. Rated operational voltage is 690 V for both the main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 380/400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16-30-22-11
The ABB AF16-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF16-30-22-12
The ABB AF16-30-22-12 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 18 A at 415 V and 18 A at 380/400 V, both at 60 °C, with rated operational power AC-3 of 7.5 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL177001R1222.
- AF16-30-22-13
The ABB AF16-30-22-13 is a 3-pole AC contactor with three normally open main contacts and four auxiliary contacts (two NO, two NC). It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational power AC-3 is 7.5 kW at 380/400 V and 4 kW at 220/230/240 V. Rated operational current AC-3 is 18 A at 415 V and 10.5 A at 690 V, at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL177001R1322.
- AF16-30-22-14
ABB AF16-30-22-14 AC contactor, manufacturer ID 1SBL177001R1422. It has three normally open main contacts, two normally open auxiliary contacts, and two normally closed auxiliary contacts. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-1 rated operational current is 30 A at 690 V and 40 °C. AC-3 rated operational power is 7.5 kW at 380/400 V and 9 kW at 415, 440, 500, and 690 V. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.36 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16-40-00-11
The ABB AF16-40-00-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V at both 40 °C and 60 °C, and 26 A at 70 °C. Rated operational current AC-3 is 18 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 15 A at 500 V, and 10.5 A at 690 V. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF16-40-00-12
The ABB AF16-40-00-12 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.