- AF16-30-22-13
The ABB AF16-30-22-13 is a 3-pole AC contactor with three normally open main contacts and four auxiliary contacts (two NO, two NC). It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational power AC-3 is 7.5 kW at 380/400 V and 4 kW at 220/230/240 V. Rated operational current AC-3 is 18 A at 415 V and 10.5 A at 690 V, at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL177001R1322.
- AF16-30-22-14
ABB AF16-30-22-14 AC contactor, manufacturer ID 1SBL177001R1422. It has three normally open main contacts, two normally open auxiliary contacts, and two normally closed auxiliary contacts. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 at 40 °C, and 16 A per IEC 60947-5-1 at 40 °C. AC-1 rated operational current is 30 A at 690 V and 40 °C. AC-3 rated operational power is 7.5 kW at 380/400 V and 9 kW at 415, 440, 500, and 690 V. Dimensions are 45 mm wide, 110.5 mm deep, 86 mm high; net weight 0.36 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF16-40-00-11
The ABB AF16-40-00-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V at both 40 °C and 60 °C, and 26 A at 70 °C. Rated operational current AC-3 is 18 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 15 A at 500 V, and 10.5 A at 690 V. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF16-40-00-12
The ABB AF16-40-00-12 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational power AC-3 is 7.5 kW at 400 V and 9 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AF16-40-00-13
ABB AF16-40-00-13 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. The main circuit is rated 690 V at 50/60 Hz; the control circuit operates at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V and 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AF16-40-00-13LU
ABB AF16-40-00-13LU is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.27 kg. The main circuit is rated 690 V, with 50/60 Hz control and main circuit frequency. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V, 440 V, and 380/400 V at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-4-1.
- AF16-40-00-14
The ABB AF16-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 30 A at 690 V AC in AC-1 at 40 °C and 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V and 440 V, 15 A at 500 V, and 10.5 A at 690 V, all at 60 °C. Rated operational voltage for the main circuit is 690 V, with rated frequency 50/60 Hz for control and main circuits. Control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; weight is 0.31 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AF16-40-00-14LU
The ABB AF16-40-00-14LU is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 77 mm deep, and 86 mm high, and weighs 0.31 kg. The main circuit is rated 690 V, with control and main circuit rated frequency 50/60 Hz. Conventional free-air thermal current is 35 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 30 A at 690 V and 40 °C or 60 °C, and 26 A at 70 °C. AC-3 ratings include 18 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 15 A at 500 V, and 10.5 A at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-4-1.