- OT1600E04CP
The ABB OT1600E04CP is a 4-pole, front-operated isolating switch with base mounting. It has a rated operational current of 1600 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A. Rated operational power for AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated insulation voltage is 1000 V, rated impulse withstand voltage is 12 kV, and rated short-time withstand current is 50 kA rms for 1 s. Conventional free-air thermal current is 1600 A at 40 degrees C. The fourth pole is switched, simultaneous function, right side. Terminals are screw type, 50 mm wide, with tightening torque 50 to 75 Nm according to IEC 60947-1. Dimensions are 480 mm wide, 372 mm high, and 309 mm deep; weight is 48 kg. Front protection is IP20, pollution degree 3.
- OT1600E04K
ABB OT1600E04K is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 414.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1600E04K-135
ABB OT1600E04K-135 isolating switch, 4-pole, front-operated, base mounting. Rated insulation voltage 1500 V, rated impulse withstand voltage 12 kV, pollution degree 3, front IP00. Rated operational current DC-20B: 1600 A and 2500 A at 1500 V DC; AC-20B: 1600 A and 2500 A at 1000 V AC; AC-21A: 1600 A at 380–415 V, 500 V, and 690 V. Conventional free-air thermal current 1600 A and 2500 A at 40 °C; fully enclosed thermal current 1600 A and 2500 A. Rated short-time withstand current 36 kA, 50 kA, or 65 kA for 0.3 s. Power loss 48 W per pole at rated operating conditions. Standards: IEC 60947-1, -3. Mechanical durability 600 cycles. Direct-mounted pistol handle, black, 274 mm, lockable. Lug terminals, 50 mm width. Dimensions 414.5 x 372 x 148.5 mm; 22.3 kg.
- OT1600E04P
ABB OT1600E04P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 414.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1600E04P-135
The ABB OT1600E04P-135 is a 4-pole front-operated switch-disconnector for base mounting, supplied with a black handle and shaft. It is rated 1500 V (Ur) with a rated insulation voltage (Ui) of 1500 V and a rated impulse withstand voltage (Uimp) of 12 kV. Conventional free-air thermal current (Ith) is 1600 A at 40 °C; conventional thermal current (Ithe) is 1600 A fully enclosed. Rated operational current AC-21A (Ie) is 1600 A at 380 to 415 V, 500 V, and 690 V. Rated short-time withstand current (Icw) is 36 kA for 0.3 s. Power loss is 48 W per pole at rated operating conditions. Mechanical durability is 600 cycles. Standards: IEC 60947-1, -3. Net dimensions: 414.5 mm width, 372 mm height, 148.5 mm depth; net weight 22.3 kg.
- OT1600E04W4P
ABB OT1600E04W4P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 594.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1600E11
ABB OT1600E11 isolating switch, 2-pole, front-operated, base mounting. Rated insulation voltage 1000 V per IEC/EN 60664-1; rated operational voltage 1000 V. Conventional free-air thermal current 1600 A at 40 °C; conventional thermal current 1600 A fully enclosed. Rated operational current AC-21A: 1600 A at 380–415 V, 500 V, 690 V, and 1000 V; AC-22A: 1600 A at 380–415 V, 500 V, and 690 V; AC-23A: 1250 A at 380–415 V, 500 V, and 690 V. Rated operational power AC-23A: 710 kW at 400–415 V, 900 kW at 500 V, 1200 kW at 690 V. Rated impulse withstand voltage 12 kV; rated short-circuit making capacity 110 kA at 690 V; rated short-time withstand current 50 kA for 1 s. Standards: IEC 60947-3. Dimensions 254.5 x 372 x 167 mm; net weight 11.9 kg. Handle and shaft not included.
- OT1600E11P
The ABB OT1600E11P is a 2-pole front-operated switch-disconnector with base mounting. It is rated 1600 A conventional free-air thermal current at 40 °C and 1600 A fully enclosed. Rated operational current is 1600 A in AC-21A at 380 to 415 V, 500 V, 690 V, and 1000 V, and 1250 A in AC-23A at 380 to 415 V, 500 V, and 690 V. Rated operational power in AC-23A is 710 kW at 400 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, rated impulse withstand voltage is 12 kV, and rated short-time withstand current is 50 kA for 1 s. It conforms to IEC 60947-3. Dimensions are 254.5 mm wide, 372 mm high, and 167 mm deep, weighing 12.8 kg.